Enseal Flashcards
Which is NOT a way by which ENSEAL x1 tissue sealers provide more surgical efficiency?
All seals made with ENSEAL x1 devices have a burst pressure greater than 240 mmhg
There are four steps to properly use ENSEAL x1 tissue sealer devices. Which of the following shows the steps in the correct order?
Close, seal, cut, open
ENSEAL x1 tissue sealer devices:
Can be used on vessels up to and including 7mm and tissue bundles as large as will fit in the jaws of the instruments
On the ENSEAL x1 tissue sealer devices, the “end tone” is one short beep. What does it mean?
It indicates the end of the cycle, the generator stops the energy delivery
ENSEAL x1 devices were designed for use exclusively with the Ethicon GEN11 generator
True, the device card plugs directly into the front of GEN11
Which of the following features of ENSEAL x1 large jaw tissue sealers results in achieving better hemostasis in thick tissue compared to ligasure impact?
Larger distal electrode surface area
What is the main ligasure competitor to ENSEAL x1 curved jaw, straight jaw, and large jaw, respectively?
Ligasure Maryland, ligasure blunt tip, ligasure impact
A colorectal surgeon is a concerned about heat when using ENSEAL x1 for dissect around vessels due to the proximity of the ureters. How should you BEST respond to his concern
The adaptive tissue technology in ENSEAL x1 senses and responses intelligently to control energy delivery for minimal thermal spread.
ENSEAL x1 tissue sealer devices can be used on vessels up to and including ________ and tissue bundles as large as will fit in the jaws of the instruments.
7mm
Which of the claims below is NOT true about how ENSEAL x1 curved or articulating tissue sealers compare to ligasure Maryland?
ENSEAL x1 curved and articulating have less steps to use than ligasure Maryland
For ENSEAL x1 tissue scaler devices, the “activation tone” is a continuous steady beeping that indicates _____. The “end tone,” one short beep indicates _____
The generator is on and active, the end of a cycle.
Which is NOT a way by which ENSEAL x1 tissue sealers provide more ACCESS?
Longer jaw and wider jaw aperture can capture more tissue per bite vs LIGASURE 5mm devices
In ENSEAL x1 tissue sealer devices, how does adaptive technology sense changes in tissue conditions?
By measuring electrical impedance
Which of the following is NOT a feature of the ENSEAL x1 articulating tissue sealer?
13mm diameter shaft
ENSEAL x1 tissue sealers primary target are high volume general, _____ and _____ surgeons using LIGASURE blunt tip, ______ and/or impact.
Colorectal, GYN, Maryland