Battery Start Limits
3 battery engine starts per hour
ENGINE CNTRL FAULT L/R
Engine start prohibited
_____ assisted cross starts are equal to one battery start
Three generator
If an external power unit is used for start, ________________________
zero battery cycle is counted
An ______________restart is equal to one battery start
in-air starter-assisted
Engine Start Limits
Three engines per 30 mins
Abort the start if N1 does not indicate rotation before _______ or if the engine stops accelerating for ______________
25% N1; 30 secs
Max. time to light-off
10 secs (first indication of fuel flow to increase in ITT)
Minimum oil temp. before increase above 80% N2
+10 C
Min. engine oil temp. (indicated on EIS)
-40C
Min. main battery temp.
-18C
At temps below -20C, the MFD may have to be operated for ______ for engine displays to be usable
10 mins
If airplane has been cold soaked in temps. below -40C, the FADEC’s must be warmed with __________followed by a power cycle with the battery switch
electrical power for at least 3 mins
Max. tailwind component
10 kts
Max. crosswind component
10 kts