Emergency Power Unit (EPU) Flashcards
EPU is
12 volt dc electric motor and a 1.5 rpm at 2000 psi pump
EPU operation is
independent of the aerial electrical system and PTO switch should be turned off.
Rated for a maximum of
3 minutes continuous operation. Extending this period of time will cause the unit to fail.
EPU can be used over a long period of time at a
7% duty cycle, which is approx 21 seconds in everything 5 minutes.
Retracting Aerial: activate the ______ mounted forward of the turntable read step
Blocking solenoid
Retracting Aerial: Activate ____ and operate appraise controls to bed the aerial. This is ____ operation
EPU / two person
Retracting Aerial: After aerial is bedded, ______
return the blocking solenoid to its original position
Retracting Outrigger: Open override control cabinet, pull red handle and hold the blocking solenoid valve. This _____.
Activate the ___. Must be done simultaneously
shuts off hydraulic fluid to the aerial system and directs flow to the outrigger valve bank. EPU
Retracting Outrigger: Activating the appropriate buttons on the outrigger valve bank, ___
the vale spool is physically shifted for the corresponding circuit.