ELECTRICAL, POWER-PLANT Flashcards
How many Generators?
Total 4
• 2 Engine
• 1 APU
• 1 RAT (emergency gen.)
Green, Red and Black circuit breakers
Green - monitored by ECAM
Red - you cannot reset
Black - just regular
What’s the power priority?
Engine, External, Apu.
Right to Left on elec. panel
What is the minimum battery voltage?
25.5 V
Guarantees at least 50% charge
What HYD systems operate Reversers?
- Green for #1 eng.
* Yellow for #2 eng.
When will you see 2 igniters during Eng. start?
- Second Auto start attempt
* Manual start
FADEC self powered by PMA at … N2?
58% N2
When do you introduce fuel during MAN ENG Start?
At least at 20% N2
NEO engine can crank up to a minute before start why?
To stabilize temps in the core of the engine
How to energize FADECS on NEO engs on ground (to check oil quantity)
Overhead panel. MX ENG FADEC pb
Engine warm up and cool down
- 5 mins before take-off
* 3 mins after landing
3 Different thrust idles
1) Modulating idle (feedback from bleeds)
2) Approach idle (with ay flaps/slats position)
3) Reverse idle (higher than others)
Do you need Blue HYD sys to operate RAT?
Yes. RAT runs the blue system but it needs to be operational
How long does it take for a RAT deployment?
8 sec
What buses RAT provides?
ESS AC and ESS DC
At What speed will the RAT stall?
140-125 kt
If Battery voltages are below the minimum, how do you charge them?
You have to check that BAT pb’s are ON and switch the external power ON
What is the meaning of the green extrn AVAIL light?
External power is plugged in and parameters are normal, you must push the EXT PWR pb to connect it.
If you have to charge BAT with EXT PWR, approx how long does it take?
20 min.
What is the important thing to remember to avoid damage to the IDG disconnection mechanism?
To push the IDG pb until the GEN FAULT light comes on, but only for a Maximum of 3 sec.
After IDG disconnection why do you get a GALLEY SHED indication on SD?
It is a reminder that the main galley has been shed automatically following the loss of one generator
Can you reconnect IDG by pressing IDG pb?
No. The IDG can only be manually reconnected by MX
What screens do you have in Electrical emergency?
PFD1 and DU (ECAM display unit)
What does the BUS TIE pb do?
Isolates both sides of the electrical system
ENGINE stabilization parameters (2/4/6/6)
2- 20% N1
4- 400° EGT
6- 60% N2
6- 600 fuel flow
Is RAT a generator?
No. its a HYD pump that pressurizes the BLUE sys witch will pressurize the EMR GEN
What happens if you press and hold red
A/THR buttons for more than 15 sec?
You will disconnect A/THR for the remainder of the flight
Electrical Emergency Synopsis
• On BATT — 2 (CA PFD, E/WD) • On RAT — 4 (CA PFD, ND, E/WD, MCDU) • 140-125 kts — RAT STALLS • 100 — DC BATT ONLY (2 screens) • 50 kts — AC ESS BUS SHED (no screens) Still have: APU fire protection and detection, VHF1