Electrical Faults Flashcards

1
Q

How long do you do a hard stable for a fault rectification?

A

7 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What level of alert requires immediate attention?

A

Level 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When does the Safety System Bypass fault light illuminate?

A

When the following has been bypassed:

Traction interlock (door bypass)

Zero speed (Tacho)

Trip

Driver safety device (PV)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How might you rectify many faults on a HCMT?

A

Reset applicable reset button

Trip and reset CB

Stable

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How many times can you reset a defect?

A

2 times

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When stabling for fault rectifications what do you do?

A

Panto lower

Turn stable/start up switch to stable for 7 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

If performing stable on mainline what do you have to do?

A

Contact TC

Platform

Under protection of home signals

Not near LVLX

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

If you have turned a safety bypass switch what do you have to do?

A

Secondary circuit

Press safety System Bypass Acknowledge button every 30 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What MR pressure drop does the safety loop open?

A

600kPa

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the MR Pressure switch for

A

Turn to Bypass when coupled to a Comeng for rescue

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the Traction Interlock Bypass switch for?

A

Door Loop Bypass

Turn if you can’t get traction because of FDCL, no door close light, door faults

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the Driver Safety Device bypass switch?

A

Hand and Foot PV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What are faults within the electrical system generally related to?

A

CBS

Traction

Auxiliary Power

  • not MR (exam)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How are most electrical faults dealt with?

A

Most electrical systems will self-isolate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Which CBs if tripped will cause the train to be declared disabled?

A

Brake Control Supply

Emergency Brake Loop Power Supply

Traction Control

Cab Activation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If Traction and Auxiliary power systems fail simultaneously what is the likely cause?

A

HSCB tripping on associated car

Caused by train or overhead fault

17
Q

If presented with Traction or Auxiliary Power fault what do you do?

A

Hint Text will instruct to push the TCU/ACU Reset button in A side Electrical Cabinet

18
Q

If Safety Loop is open and Emergency Brake not releasing what could be the causes?

A

Trip

Emergency push button

CB - EB CB tripped

Hand or Foot PV

Operator Enable CB tripped

VICERS

MR pressure below 600