Door Faults Flashcards
Door closed and inhibited
Grey
Door closed but not inhibited
Green
Door open
White
Door failed (defective)
Red
Door isolated
Yellow
Unknown status
Empty
How many times will a door attempt to close?
4
When a door fails in open position what do you do?
Use CCTV to observe any obstruction
Make PA announcement asking passengers to remove
If door remains open how do you manually close?
PA, TEC, Cab unattended
Close door … if won’t close …
Pull DER stage 1 and release
Wait 20 seconds
Pull DER stage 2
Grip each door and pull closed
Return DER to upright position and close cover
Turn Tri-key 90 deg. clockwise in mechanical door isolation port
Observe iso. lamp and door open buttons illuminated red
Push door open button to confirm door remains closed
Apply stickers
Check TMS door status to confirm door isolated
TMM
What happens to DERs when door is isolated?
Internal and external DERs will not function
If you are unable to manually close a door what happens?
Traction Interlock Bypass
Detrain passengers and shunt to nearest siding
If you have to turn Traction Interlock Bypass what happens?
Run on secondary circuit pushing Safety System Bypass Acknowledge button every 30 seconds
What does it mean if you get no/extinguished door close light?
An open cab door has been detected
What happens if you have to go to rear cab how do you ensure cab door has been closed?
Activate cab and check door closed effectively on TMS pictogram
When a DER is pulled how long do you have to press the DER Inhibit button
20 seconds