Electrical Flashcards
What are the sources of airplane generated AC power?
Two 115VAC, 60kVA engine driven variable frequency generators (67.5kVA for 5 minutes, 75kVA
for 2minutes and 90kVA for 5 seconds)
One 115VAC, 60kVA APU generator (67.5kVA for 5 minutes, 75kVA for 2 minutes and 90kVA for
5 seconds)
One 115VAC, 9kVA Ram air turbine when all other AC sources have been lost (13.5kVA for 5
minutes, 18kVA for 5 seconds)
In the event of single generator operation, which AC Buses are automatically shed?
None; a single generator supplies power to all three AC buses (although, some high load users,
such as certain hydraulic system pumps, are load shed)
What does an EXT AC “AVAIL” annunciator on the ELECTRICAL panel indicate?
External AC power is connected
Power is the correct voltage and frequency
External Power is not on line
Where is the location of the external ground power panel? (FCOM2, Doors)
Lower body fairing below the right engine
Which buses are powered with EXT AC connected, on and in “normal mode”?
All AC and DC buses are powered
What is the AC priority source for AC BUS 1 and 2?
Onside engine VFG
APU Generator
External AC Power
Opposite side engine VFG
What is the voltage and ampere-hours rating of the batteries?
24VDC, 28Ah
What is the minimum battery voltage for start?
22VDC
Where are The APU and Main Batteries located?
APU battery is in the belly fairing compartment below the baggage bay door
Main battery is in forward equipment bay in the nose of the airplane
How long will the aircraft main batteries last as the sole source of power?
Minimum of 5 minutes
How do you know when a battery is not being charged?
A Cyan DISCHARGING indication on top of the battery on the ELEC synoptic page
A cyan BATT DISCHARGING CAS message
If the ELECT synoptic page shows 24VDC or less and decreasing, it is not being charged
Which DC Buses are automatically shed during a single TRU Fail?
None; all remain powered
Which DC Buses are automatically shed during a TRU 1 and 2 Fail?
DC BUS 1 and 2
Can a thermal circuit breaker be reset from the Electronic Circuit Breaker Application (ECB)?
No, the affected circuit breaker can only be manually reset at its location
Will a physical CB trip generate a CAS message?
Yes, a cyan CB TRIP CAS message