Describe load shed on engine start
A
1) The #2 C Elec Hyd pump sheds with only one generator and all of the other 3 ELEC HYD pumps operating
2) The L Elec Dem Pump sheds on the ground during engine start with only one generator
3) C Tank Fuel Pumps (if installed) are inhibited any time engine N2 is less than 50% N1
4) The Utility Busses are shed during engine start when the APU is supplying both electrics and air. Only the utility bus powered by the APU will shed.