ELEC Panel Flashcards

1
Q

What is the minimum battery voltage?

A

• 25.6V

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What would a pilot do if BAT voltage is 25.5 or below on originatingpreflight?

A

• Charge the batteries with external power by selecting BAT pushbuttons to AUTO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How long should the batteries be charged?

A

• 20 minutes, then recheck the voltage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Explain how to conduct the BAT check. What if it fails the test?

A

• Select ELEC on ECAM• Turn BAT 1 & 2 OFF then ON• Check BAT charge current is < 60 amps and decreasing within 10 seconds• If it fails the test, wait until the end of the charging cycle, and repeat the test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Describe the electrical power system.

A

• The electrical power system consists of a three-phase 115/200-volt 400- hertz constant frequency AC system and a 28-volt DC• Normally, the system produces alternating current, some of which is then transformed into direct current for certain applications.• Each of the aircraft’s three generators can supply the whole network.• If all normal AC generation is lost, an emergency generator can supply AC power.• If all AC generation is lost, the system can transform DC power from thebatteries into AC power.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

If all AC power is lost, what happens?

A

• DC power from the batteries is converted into AC.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What would be an expected indication in the GEN pushbuttons prior to engine start?

A

• FAULT indication.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Define and describe an IDG.

A

• Integrated Drive Generator• Takes variable engine output and gives a constant output.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How would a pilot disconnect an IDG?

A

• Lift the red guard and push the IDG pushbutton, being careful not to hold the pushbutton for longer than three seconds.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How would an IDG be reconnected?

A

• This cannot be done by the flight crew – it is a maintenance function.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Describe the function of the BUS TIE in AUTO.

A

• Allows a single source of power to run entire electrical system• Allows connection of the APU GEN or EXT power to system• Inhibits multiple sources connected simultaneously

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

If GEN 1 fails to supply AC Bus 1, what happens?

A

Gen 2 (or APU GEN if available) powers the system through the bus tie.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How is the AC ESS bus normally powered?

A

• From AC bus 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

If AC BUS 1 fails, how is the AC ESS bus powered?

A

• AC bus 2 automatically feed the AC ESS bus.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What indication will be present on the ELEC panel that AC BUS 2 is feeding the AC ESS bus?

A

• AC ESS FEED ALTN light illuminated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What does a GALLEY fault light indicate?

A

• At least one generator load is above 100% rated output.

17
Q

Explain the AUTO function of the GALLEY pushbutton.

A

• Sheds main galley if only 1 GEN is available

18
Q

How is the BATTERY BUS normally powered?

A

• DC BUS 1 through the DC tie contactor

19
Q

What buses are powered by the EMER GEN?

A

AC ESS BUSAC ESS SHEDDC ESS BUS by ESS TRDC ESS SHED

20
Q

What is the difference of the APU GEN FAULT and the ENG GEN FAULT?

A

• Both are indicators of a line contactor open. The difference is that the ENG GEN fault may also indicate a fault detected by the ENG GCU.

21
Q

What does a BAT FAULT light indicate?

A

• Battery charging current outside limits.• BAT contactor opens.

22
Q

When are the batteries connected to the battery bus?

A

• APU start• Battery charging• AC BUS 1 and 2 not powered and airspeed below 100 knots