DWV take 2 Flashcards
The maximum horizontal length of a w.c fixture drain is?
10 ft (3m)
A vent stack shall be installed to protect the base of every soil or waste stack that passes through more than:
4 storeys
What is the hydraulic load of a 3” floor drain in a public washroom?
no load
The size of the portion of vent pipe that terminates through the roof shall not be less than:
3”
Any roof vent terminating into the open air shall be located at a distance of not less than:
3.5m away from any window, door or other opening
The min developed length of a trap arm shall not exceed:
2 x the pipe diameter
Strap hangers shall not be used to support horizontal pipe greater than:
4”
Fixtures that drain into a vertical section of a relief or circuit vent shall not have a hydraulic load of?
1 1/2 FU
All fixtures shall have a trap w/ a water seal of?
not less than 1 1/2 “ (38mm)
A trap used to carry acid waste shall have a water seal of:
not less than 2” (50mm)
How many fixture units are permitted to drain into a soil or waste stack if the stack was to act as a relief vent?
6 FU each
The max number of a water closets allowed on a 3” soil stack is?
6 water closets
The rate of discharge through an 1 1/4” fixture outlet pipe is called a/an
fixture unit
Where a building trap is installed, a fresh air inlet shall be installed on the building drain upstream of the trap:
2.5.5.4
as close as possible to the trap and w/in 1.2m of the trap
The trap weir is?
The highest part of the lower interior surface
A vertical pipe means:
45 degree from the vertical
The max distance bn hangers on a horizontal run of ABS plastic pipe shall be:
1.2m (4’)
A building sewer begins outside a building at a point?
1m from the building wall
The total fall of a fixture drain from the trap weir to the vent fitting shall not exceed:
two times the diameter of the pipe
Any vent pipe shall extend vertically above the flood level rim of a fixture:
to adjust above the flood level rim before connecting to another vent
The min size of a fresh air inlet for a 7 storey building is:
4”
A shower receptor for 2 or 3 heads is equal to a hydraulic load of:
3 fixture units
A kitchen sink with a domestic type garbage disposal unit installed on it has a hydraulic load of?
1 1/2 FU
A 2” trap not listed in table 2.4.9.3 has a hydraulic load of?
3 FU
The max number of FU that may be connected to a horizontal branch off a 2” stack that passes through 5 storeys is?
6 FU
The max number of FU that may be connected to a 3” stack of 60 meters in developed length is:
102 FU
The max number of FU that may be connected to a 4” building drain at uniform grade of 1 in 50 is?
240 FU
The size of a trap / waste opening for a potato peeler is?
2”
The size of a trap / waste opening for a beauty parlor basin is?
1 1/2”
The min size vent for a 2” trap is?
1 1/2”
The max cumulative change in direction of a trap arm serving a lavatory is?
135 degrees
A branch cannot be connected w/in 1.5m of the base of the stack:
- receives a discharge of 30 of more FUs
- receives a discharge from fixtures located on 2 or more storeys
A common cause of trap seal loss in a properly vented system is?
evaporation
An ABS stack 15m in length, when subjected to a temp change of 50 C, would have a linear expansion of about?
70 mm
A-2.3.3.9
The trap seal refers to the vertical distance measured from?
the trap weir to the trap dip
In testing a 5 storey (15m) stack with water, the pressure at the base of the stack on the gauge would read?
147 kPa
If 8 water closets are required in a washroom, how many urinals could be substituted for w.c’s?
5
(2/3)
The max length of an offset on a 4” soil / waste stack serving as a wet vent is?
max 2.5 m
You must connect a sanitary building drain w/ a combined building sewer. If an open air restaurant is located on the roof of the building, and the roof drain has to be located w/in 1 m of the patio, what must you do to ensure that your rough-in passes inspection?
Place a running trap / clean-out on the storm building drain prior to its connection w/ the building sewer
What is the min length of a trap arm serving a lavatory?
2 1/2”
Which arrangement may allow a fixture to self-siphon?
Trap too far below fixture
If you have a 4” building drain connected to a 3” soil stack, what would the size of the c/o at the base of the stack be?
4”
2.4.7.2
What is the min grade on a building drain?
1%
1/8
What is the primary function of a p-trap?
Keep sewer gases from entering the building
Trap arm size are based on?
The size of the fixture outlet pipe
What would be the size of a trap that serves two lavatories that are in the same room?
1 1/2”
What size of vent terminal would be required for a 1 1/2” vent?
1 1/2” x 3”
2.5.6.5