DLSS, Mk. III Flashcards
What is the floodable volume of a LWDS Flask?
0.935 ft cubed.
Where are the relief valves located on the Mk. III?
Control Console (ALP-V-308), Volume Tank (ALP-V-207), HP Flasks (AHP-V-505,506,507), and Roof Rack Assembly (AHP-V-603).
How many standard cubic feet are contained in a single flask at 3,000 psi?
191 scf
What system are components labeled under the 400 series a part of on the LWDS?
Air Compressor Assy.
What system is a valve in the 500 series from?
HP Air Flask Assy.
What system is a valve in the 200 series a part of?
The Volume Tank Assy.
What system is a valve in the 300 series a part of?
The Control Console Assy.
What system is a hose in the 100 series a part of?
Deck Hose Assy.
What system is a valve in the 600 series a part of?
The Roof Rack Assy.
What is the minimum number of primary HP air racks for a Mk. III, Config. 2?
3.
What is the MMP for a KM-37 Diver diving to 60FSW? Mk. 21 At the same depth?
165psi for KM-37, 120psi for Mk. 21.
What are the components of the MK. III system?
Volume Tank Assembly, Control Console Assembly, Flask Rack Assemblies(primary and secondary), Roof Rack Assembly, and the deck hose assembly.
What is a DFS, and what DFSs do we have on the Dive Boat?
Departure From Specification. DS01 has two DFS, one for the modified racks, and another for the charging assembly (no roof rack).
What is the difference between the Mk. III Mod 0 and the Mk. III Mod 1?
The Mk. III Mod 1 is identical to the Mk. III Mod 0, except that the control console and volume tank have been modified to operate at 5000psi for use with the ASRA.
What is the difference between the Mk. III Config. 2 and the Mk. III Config. 3?
The Mk. III Config 3 has two secondary supply racks as opposed to one with the Config. 2.