DC Flashcards
INCREASE DC LOK
WHO IS THE DAMAGE CONTROL OFFICER
CDR EHNES
WHO IS THE DCA
LCDR LEPPO
WHO IS THE SHIPS FIRE MARSHAL
CWO3 JONES
HOW MANY AFFF STATIONS ARE ON BOARD
20
HOW MANY AFFF STATIONS ARE INJECTION ONLY AND WHICH ONES ARE THEY
4
1,2,11,12
HOW MANY WAYS CAN YOU OPERATE A STATION AND WHAT ARE THEY
4
PUSH BUTTON, SOPV, LOCAL MOTOR CONTROLS, BREAKERS
WHAT DOES THE AFFF PROPORTIONING SYSTEM SUPPLY
HANGAR BAY SPRINKLERS, HOSE REELS, WEAPONS ELEVATOR FLOODING, BILGE SPRINKLING
WHAT DOES THE AFFF INJECTION SYSTEM SUPPLY
FLIGHT DECK COUNTER MEASURE WASH DOWN
HOW ANY COUNTER MEASURE WASHDOWN MIXING STATIONS ARE ONBOARD AND WHAT DECK ARE THEY ON
21, 03
WHAT DOES GROUP 21 SERVE AND WHAT STATION DOES IT COME OFF OF
SERVES THE BOMB FARM, STATION 17
HOW MANY AFFF TRANSFER TANKS DO WE HAVE AND WHERE ARE THEY LOCATED
2
ONE ABOVE EACH O2N2 PLANT
HOW MANY TRANSFER PUMPS DO WE HAVE AND WHAT ARE THEY RATED FOR
2
360 GPM
WHERE ARE THE TRANSFER PUMPS LOCATED
1 IS INBOARD OF AFFF STATION 6
2 IS OUTBOARD OF AFFF STATION 13
WHERE ARE AFFF STATIONS 1 AND 2 LOCATED
AS FAR FWD ON THE 2ND DECK AS YOU CAN GO
WHERE IS AFFF STATION 3 LOCATED
STBD SIDE OF THE FWD SCULLERY
WHERE IS AFFF STATION 4 LOCATED
OVER THE FWD EDG SPACE FRAME 40
WHERE IS AFFF STATION 5 LOCATED
STBD SIDE OF FWD GALLEY
WHERE IS AFFF STATION 6 LOCATED
Port side fwd galley soda fountains
WHERE IS AFFF STATION 7 LOCATED
OUTSIDE S-1 OFFICE
WHERE IS AFFF STATION 8 LOCATED
OUTSIDE THE ENTRANCE TO 1 RAR
WHERE IS AFFF STATION 9 LOCATED
AFT MESS DECKS
WHERE IS AFFF STATION 10 LOCATED
BELOW 1B REPAIR LOCKER
WHERE IS AFFF STATION 11 LOCATED
COS LADDERWELL
WHERE IS AFFF STATION 12 LOCATED
MIDSHIP PULPER
WHERE IS AFFF STATION 13 LOCATED
OUTSIDE OF THE RX OFFICE
WHERE IS AFFF STATION 14 LOCATED
STBD SIDE OF AFT GALLEY START LINE
WHERE IS AFFF STATION 15 LOCATED
OUTSIDE ENTRANCE TO 3 AIRCRAFT ELEVATOR MACHINERY ROOM
WHERE IS AFFF STATION 16 LOCATED
XOS PWAY
WHERE IS AFFF STATION 17 LOCATED
UNDER THE AFT PULPER
WHERE IS AFFF STATION 18 LOCATED
NEAR REP 3
WHERE IS AFFF STATION 19 LOCATED
OUTSIDE SHIPS LAUNDRY
WHERE IS AFFF STATION 20 LOCATED
ENGINEERING BERTHING
WHAT IS BROMO-TRIFLOURO -METHANE
HALON 1301
WHAT ACTIVATES HALON RELEASE
5LB C02 ACTUATOR
WHAT ARE HALON CYLINDERS PRESSURIZED WITH
NITROGEN
HOW MANY C02 ACUTATION POINTS ARE THERE FOR HALON RELEASE AND WHAT ARE THEY
2
LOCAL AND REMOTE
WHAT IS THE REQUIRED SOAK TIME BEFORE ENTERING A SPACE FLOODED WITH HALON
15 MINUTES SOAK TIME, 15 MINS VENTILATION TIME
HOW MANY HALON STATIONS ARE ON BOARD
13
HOW MANY MAIN SPACE HALON STATIONS ARE THERE
5 (FWD AND AFT EDG, 2+3 JP5 PUMP ROOM, 1B SHAFT ALLEY)
WHAT IS BROMO-CHLORO-DIFLUORO-METHANE
HALON 1211
WHERE WOULD YOU FIND A HALON 1211 STORAGE TANK
HB 1 STBD SIDE JUST FWD OF DECK EDGE DOOR 1
WHAT IS HALON 1211 USED WITH
PKP
WHAT DOES APC STAND FOR
AQUEOUS POTTASSIUM CARBONATE
WHAT SPACES ONBOARD WOULD YOU FIND APC IN AND FOR WHAT EQUIPMENT
GALLEYS
USED FOR DEEP FRYERS
HOW MANY SPACES ON BOARD ARE SUPPORTED BY APC
7
HOW MANY MANUAL WAYS ARE THERE TO ACTUATE APC AND WHAT ARE THEY
3
REMOTE MANUAL CONTROL BOX, PRESSURE RELEASE CONTROL BOX, APC CYLINDER
WHAT IS THE AUTO ACTUATION FOR APC AND WHEN DOES THAT HAPPEN
IT IS A FUSABLE LINK, IT MELTS AT 360 DEGREES
HOW MANY FIXED FLOODING C02 SYSTEMS ARE THERE ON BOARD AND WHERE ARE THEY
1, IN THE MOTOR REWIND SHOP BELOW THE AFT MESS DECKS
HOW DO YOU LIGHT OFF C02 FIXED FLOODING
BREAK THE GLASS AND PULL THE CHORD
HOW MANY C02 HOSE REELS ARE ON BOARD
1
IT IS IN THE FANTAIL JET SHOP
HOW DO YOU LIGHT OFF A C02 HOSE REEL
PULL THE PIN ON THE 1ST CYLINDER AND LIFT THE LEVER
HOW LONG DOES A 50 LB CO2 BOTTLE LAST
1 MINUTE
WHAT ARE THE 4 STAGES OF A FIRE
GROWTH, FULLY DEVELOPED, FLASHOVER, DECAY
WHAT FANS ARE USED FOR DESMOKING AND WHAT ARE THEY
BOX FAN 3200, RAM FAN 2000
HOW MANY DC REPAIR LOCKERS ARE ON BOARD
10
WHERE IS 1A REP LOCKER LOCATED
AFT PULPER
WHERE IS 1B
ABOVE AFFF 10
WHERE IS 1F
BETWEEN THE PIPE SHOP AND FWD O2N2
WHERE IS 7A
INBOARD OF B/A CRANE
WHERE IS 7B
NEXT TO THE ATO OFFICE
WHERE IS 7F
NEXT TO V-4 BERTHING
WHERE IS REP 2
NEXT TO FWD EDG
WHERE IS REP 3
NEXT TO THE SUPPLY BERTHING LOUNGE
WHERE IS REP 4
BY SECURITY DISPATCH
WHERE IS REP 5
MIDSHIP PULPER
WHAT IS THE RANGE OF A 27LB PKP BOTTLE, HOW LONG WILL IT LAST
21 FEET, 10-11 SECONDS
WHAT IS THE RANGE OF AN 18 LB PKP BOTTLE, HOW LONG WILL IT LAST
18-19 FEET, 10-11 SECONDS
WHAT IS THE RANGE OF A 15 LB C02 BOTTLE AND HOW LONG WILL IT LAST
4-6 FEET, 45 SECONDS
WHAT IS THE RANGE OF AN AFFF EXTINGUISHER AND HOW LONG WILL IT LAST
15 FT AND 60 SECONDS UNDER CONTINUOUS USE
WHAT DOES NFTI STAND FOR
NAVAL FIREFIGHTING THERMAL IMAGER
WHAT ARE THE 2 TYPES OF NFTI BATTERY PACKS
RECHARGABLE AND A 10AA BATTERY PACK
A BATTERY PACK WITH FRESH BATTERYS WILL LAST HOW LONG FOR A NFTI
60-90 MINS
WHAT MODEL OF NFTI DO WE USE ON BOARD
K-90 TALISMAN
WHAT ARE THE 3 TYPES OF PORTABLE EDUCTORS
S TYPE, MINI PERIJET, AND THE PERI JET
WHAT ARE THE INLET AND OUTLET SIZES OF THE S TYPE EDUCTOR
INLET:1 1/2 “
OUTLET 2 1/2”
WHAT ARE THE INLET AND OUTLET SIZES OF THE PERI JET EDUCTOR
INLET : 2 1/2” INLET
OUTLET: 4 “
WHAT ARE THE 4 TYPES OF PIPE PATCHES WE USE
SOFT PATCH, JUBILLEE, E WARP, BANDING PATCH
WHAT IS THE MAX PSI FOR ALL PIPE PATCHES
ALL BUT THE JUBILLEE HAS A LIMIT OF 150, THE JUBILEE IS RATED FOR 100
HOW MANY SIZE E WARPS DO WE HAVE
2
WHAT ARE THE BEST WOODS TO USE FOR SHORING
DOUGLAS FIR AND YELLOW PINE
WHAT ARE THE THREE TYPES OF SHORING
I TYPE, K TYPE, AND H TYPE
WHAT ARE THE TWO SIZES OF METAL SHORES
3 TO 5 FT
6 TO 11 FT
WHAT ARE THE CAPACITIES FOR METAL SHORING
3-5FT:12K TO 20K LBS
6-11FT: 6K TO 20K LBS
WHAT ARE THE FLOW RATES FOR THE 1 1/2” vari nozzle and where ARE THEY USED
95 GPM, INSIDE THE SKIN OF THE SHIP
125 GPM, OUTSIDE THE SKIN OF THE SHIP
WHAT ARE THE PATTERNS OF THE VARI NOZZLE
SOLID STREAM, NARROW V, WIDE V, FLUSH
WHAT ARE THE TWO TYPES OF SCBAS WE USE
30 MIN AND 45 MIN BOTTLES
WHAT TYPE OF AIR DO WE FILL THE SCBAS WITH, AND TO WHAT PSIG
TYPE D AIR, 4500 PSIG
NAME 2 ITEMS IN THE INVESTIGATOR KIT
FLASHLIGHTS, TOOL BELTS
HOW MANY PHYSICAL STATES ARE CHEMICALS FOUND TO EXIST IN
SOLID, LIQUID, GAS
HOW DO CHEMICAL AGENTS ENTER THE BODY
RESIPRATORY TRACT, CONTACT WITH SKIN, WOUNDS OR CUTS, THROUGH THE EYES
WHAT AGENTS IN VAPOR FORM WILL THE M-256A1 CHEMICAL AGENT DETECTOR KIT DETECT
BLISTER, NERVE, LEWISITE, AND BLOOD AGENTS
WHAT ARE THE FOUR CASUALTY AGENTS USED IN CHEMICAL WARFARE
CHOKING, BLOOD, BLISTER, NERVE
WHAT CHEMICAL AGENTS WILL M-8 PAPER DETECT
LIQUID V AND G NERVE, AND H-TYPE BLISTER AGENTS
WHERE WOULD YOU FIND THE COLOR COMPARISON CHART FOR M-8 PAPER
INSIDE FRONT COVER OF THE BOOKLET
WILL M-8 PAPER DETECT AN AGENT IN VAPOR OR GAS FORM
NO, ONLY LIQUIDS
WHAT COLOR WILL M-9 PAPER TURN IF A CHEMICAL AGENT IS DETECTED
ANY SHADE OF RED DOTS
WHERE SHOULD M-8 OR M-9 PAPER BE POSTED PRIOR TO AN ATTACK
VENT DUCTS, WATERTIGHT ACCESSES, AND ANYWHERE THE SHIPS CBR BILL SAYS TO
WHAT IS THE EFFECTIVE LIFE OF THE GAS MASK FILTER CANISTERS
60 DAYS ONCE REMOVED FROM THE STOWAGE CAN IN A NON CONTAMINATED ENVIRONMENT, 30 DAYS IN A CONTAMINATED ENVIRONMENT, AND ONE BLOOD AGENT ATTACK.
WHAT IS CONTAINED IN THE M-256A1 DETECTOR KIT
12 SAMPLER DETECTORS, 1 BOOK OF M8 PAPER, AND A SET OF OPERATING INSTRUCTION CARDS
HOW DOES THE M-291 DECON KIT DECONTAMINATE
THOROUGH WASHING, ABSORPTION, AND NEUTRLIZATION
HOW MANY PACKETS ARE IN THE M-291 DECON KIT
6, ENOUGH FOR 3 COMPLETE SKIN DECONTAMINATIONS
HOW MANY AUTO INJECTORS OF ATROPINE AND 2 PAM CHLORIDE ARE ISSUED TO EACH PERSON
3 ATROPINE AND 3 2PAM
ATROPINE AND 2PAM CHLORIDE ARE ONLY SED AFTER EXPOSURE AND SYMPTOMS OF WHAT KIND OF CHEMICAL AGENT
NERVE AGENT
WHAT DOES ACPG STAND FOR
ADVANCED CHEMICAL PROTECTICE GARMET
WHAT MAKES UP AN ACPG SUIT
TROUSERS, BOOTS, GLOVES, GLOVE INSERTS
WHAT MUSE YOU ENSURE IS IN YOUR TROUSERS AND COAT PRIOR TO DONNING
THE CHARCOAL LINER
WHAT IS THE SHELF LIFE OF AN ACPG
5 YEARS
WHAT IS THE OPERATIONAL LIFE OF AN ACPG
45 DAYS WORN UNCONTAMINATED, 24 HOURS CONTAMINATED
HOW MANY TIMES CAN YOU WASH AN ACPG
6 TIMES IN 120 DAYS