Cylinder Procedure (PN 376) Flashcards
How do you spell asettlene?
A C E T Y L E N E
At a cylinder incident what is our first consideration?
LIFE
Failure of a steel cylinder will result in fragments being thrown how far?
200 Metres
How big might a fireball of flammable gases be if a cylinder fails?
25 Metres
What is a BCGA CP?
British Compressed Gas Association Competent Person
What does CAP stand for?
Cylinder Assessment Process
Where is their a CAP aide memoir?
No 6 with BA board
BA must be worn within how many M’s of cylinder?
25 Metres
Which cylinders which are alight may be turned off?
Those alight from the valve group inlet/outlet, not those alight from the neck of the cylinder
What should a FF consider USING when approaching cylinders? And what are they likely to set up?
Substantial Cover
A Cooling Jet
How long must an Acetylene cylinder be cooled?
Min 1 hour then CAP tested
At what temperature does a steel cylinder lose its tensile strength?
300 degrees C
200 - 250 for Aluminium
How is an Acetylene cylinder designed to fail?
Ductile mode - along its length
When are cylinders at greatest risk of failure?
When there is direct flame impingement
What are the four types of cylinder construction?
Welded cylinders (2 steel parts welded together) Drawn steel (1 part) Aluminium Cylinders Composite Cylinders (resin and woven fabric sometimes wrapped around an aluminium lining
Gases can be? (4)
Flammable
Toxic
Corrosive
Asphyxiant
What 3 particular types of premise might be reasonably assumed to contain cylinders?
Railway Arches
Vehicle Workshops
Building Sites
Why apply a cooling Jet?
Restores Tensile Strength
What 2 things must be considered with cylinders not yet involved?
Remove and protect with Jets
What 3 things may indicate that a cylinder has not been involved in fire?
Intact paper labels and plastic rings
Undamaged hoses
Paint not blistered or blackened