CVCS Flashcards

1
Q

If all charging pump breakers go open what happens to the letdown HCV’s?

A

HCV 1200A, 1200B and 1200C go closed when no charging pumps are operating.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Other than CVCS what other systems use the letdown filter?

A

RHR and Reactor Purification

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is Normal Excess letdown flow?

A

15GPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When purging the VCT what gas is added?

A

Nitrogen.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What happens on a high VCT signal?

A

LCV-1115A will go full open and divert to the PDT.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Other the the MCR, where can we operate the charging pumps from?

A

Auxiliary Shutdown Panel.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Why do we use caution when raking the charging pump breakers.

A

Could possibly trip the other charging pump.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What position do you place the charging pump dampers when you are done with manual operation?

A

The original, pulled out position will allow it to operate in automatic.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Which flows use the seal return heat exchanger

A

Excess Letdown
Charging pump mini flow recirc
Seal return

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Where is excess letdown normally aligned to.

A

Normally directed to the seal return header and diverted to the PDTT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

1204 A and B reposition to what on an SI signal?

A

Closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Do we use PCV-1114 during a Boration?

A

PCV-1114 is NOT used during a boration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Auto closure and Fail positions for:

LCV-1460 A&B

A
Auto closes on PZRlevel of 14.4%
Fail closed (app R)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Auto closure and fail position of CH-TV-1204 A&B?

A

Close on SI signal and fails closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Auto closure and fail position of PCV 1145

A

Controls back pressure at 300#

Fails open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Auto and fail position of TCV-1143

A

Divert letdown to VCT at 145 F.

Fails to divert

17
Q

fail position of HCV-1244

A

Fails to Direct letdown to VCT

18
Q

VCT Controller 1115 controls what?

A
85% - Divert 115A to PDT
82% - High level alarm
34% - Auto makeup stops
27% - Auto makeup starts
24% - low level alarm
13% - signal to isolate VCT (2/2 w/ 1112)
19
Q

Sources of water to Normal CHP suction?

A
VCT
RWST
B LHSI pump
Other unit RWST
Emergency Borate line
Manual Borate
Manual Dilute
Blender
Chemical addition tank
Seal return
20
Q

Sources of water to the Alternate CHO suction

A

A LHSI pump discharge only

21
Q

Flowpath from the Normal CHP disch header?

A

Normal CH line to B cold leg
RCP seal injection
Aux Spray
HHSI to Hot or Cold legs

22
Q

Alternate CHP Disch possible flowpath?

A

Loop fill
RCP seal injection
HHSI to Hot or Cold legs

23
Q

Which two CH pumps can use the cross tie?

A

1-CH-P-1C

2-CH-P-1C

24
Q

What 3 flows connect into the seal return line.

A

Seal return
Excess Letdown
CHP miniflow recirc

25
Q

State the CHP auto starts…

A
For each: -Low disch pressure of <1176 psig for 10sec.
- SI signal
     (A - A, B - B, C - A or B)
-UV/DV on opposite emergency bus
-Both other CHP breakers open
26
Q

CH pump trips:

A

Phase Over current or Ground
Switch in PTL
A) UV/DV on H bus and C normal pump breaker closed and running
B) UV/DV on J bus and C alt breaker closed and pump running
C) UV/DV on H bus and A pump still running with breaker closed after 1sec