CVCS Flashcards
If all charging pump breakers go open what happens to the letdown HCV’s?
HCV 1200A, 1200B and 1200C go closed when no charging pumps are operating.
Other than CVCS what other systems use the letdown filter?
RHR and Reactor Purification
What is Normal Excess letdown flow?
15GPM
When purging the VCT what gas is added?
Nitrogen.
What happens on a high VCT signal?
LCV-1115A will go full open and divert to the PDT.
Other the the MCR, where can we operate the charging pumps from?
Auxiliary Shutdown Panel.
Why do we use caution when raking the charging pump breakers.
Could possibly trip the other charging pump.
What position do you place the charging pump dampers when you are done with manual operation?
The original, pulled out position will allow it to operate in automatic.
Which flows use the seal return heat exchanger
Excess Letdown
Charging pump mini flow recirc
Seal return
Where is excess letdown normally aligned to.
Normally directed to the seal return header and diverted to the PDTT
1204 A and B reposition to what on an SI signal?
Closed
Do we use PCV-1114 during a Boration?
PCV-1114 is NOT used during a boration
Auto closure and Fail positions for:
LCV-1460 A&B
Auto closes on PZRlevel of 14.4% Fail closed (app R)
Auto closure and fail position of CH-TV-1204 A&B?
Close on SI signal and fails closed
Auto closure and fail position of PCV 1145
Controls back pressure at 300#
Fails open