Communications Flashcards
Immediate CIDS entry
Can be accomplished with the approval of the Administrative Deputy Chief
Use the eCIDS application to enter the proposed immediate CIDS
After submitting the entry! Notify Admon BC by phone to inform of pending immediate CIDS
Immediate CIDS always appear at the top of a units pending list and will be in bold print
Submission of immediate CIDS will generate automatic email notifications to the next level of immediate approval up to and including the FDOC
A fire protected structure occupied as a High Rise Multiple Dwelling should be classified as
CL2R
A fire-protected structure which is constructed, renovated, or repaired using metal “C” joists or steel bar joist should be classified as
CL2LW
A non-Fireproof structure which is constructed renovated or repaired using any type of structural lightweight materials should be classified as
CL3LW
A wood frame structure which is constructed, renovated, or repaired using any type of structural Light-Weight materials should be classified as
CL4LW
A structure which is constructed renovated, or repaired using “Mass Timber” engineered building products should be classified as
CL6MT
Bowstring Truss
BWSTRG
Special CIDs designation
CFR Hold
CFRH
Special CIDs designation
What are the requirements for a CFR Hold building?
Need on duty personnel trained in CPR, trained to provide oxygen, trained to use defibrillator
All necessary equipment is available to trained personnel
CFRH buildings must be operational on a 24/7 basis
The facility must be “CFR Hold Eligible” on all floors of the building
Major Alteration
MJALT
Special CIDs designation
What should the Major Alteration designation be used for?
For existing structures which have extensive alterations that involve horizontal extensions, vertical extensions, or extensive changes to the structure changing its occupancy or purpose
Pre-Incident Guidelines
PG
Special CIDs designation
Rehabilitated
REHAB
Special CIDs designation
What should the Rehabilitated designation be used for?
For existing structures which have extensive repairs or renovations that do not involve any horizontal extension, vertical extension, or extensive changes to the structure changing its occupancy or purpose
Mega High Rise
MEGA
Special CIDs designation
Any building over 800’
Units receiving a verbal alarm while in quarters must notify dispatch as soon as possible via
Telephone or the apparatus radio
When receiving a verbal, you must indicate to the dispatcher
The nature of the incident you are responding to
The location of the incident
If additional assistance is required