Comfort Cooling Troubleshooting Flashcards
The required condenser air flow is approximately
1000CFM per ton
A dirty condenser prevents the rejection of heat and causes
High head pressure
A condenser fan motor with sleeve bearings should be lubricated
2 times per year
Improper blower pulley alignment can cause
Unnecessary wear
Erratic speed
Premature belt failure
V-Belt tension should be set to about
1 inch
To add refrigerant to a partially charged air conditioning system a technician should read the manifold gauges and then
Compare to a Pressure Temperature Chart
Starting up an air conditioning system with the indoor temperature at 85 degrees f and the Rh at 70% would be considered
An excessive load
During a complete loss of charge condition with a leak on the systems low side and the systems low pressure cut-out control has opened the technician must consider
Finding and repairing the leak
Contaminant in the system
The compressor will not start until the system is recharged
After a system evacuation ___________ can cause a micron gauge to rise from 250 microns to 500 microns before leveling off
Excessive contamination
To clean an excessively moisture contaminated system a technician may perform a
Triple evacuation
A full or partial restriction of the capillary tube is often the result of
Too much oil charge
Incorrect oil viscosity
Liquid refrigerant entering the compressor crankcase
An air conditioning system with a fluctuating evaporator pressure would most likely be the result of a
Defective AEV
A system operating with a loose thermal expansion valve sensing element would cause the systems superheat to be
Too low
Any evaporator with a pressure drop in excess of _________ should use a thermal expansion valve with an external equalizer
2.5 psig
Any system operating with a thermal expansion valve can automatically adjust to a change in the load condition. In order to supply an adequate volume of refrigerant the system must also utilize
A receiver