CML Flashcards
What does CML stand for?
Command Management LAN
What two networks is CML divided into?
NIPRNET (Non-secure Internet Protocol Router Network) & SIPRNET (Secure Internet Protocol Router Network)
What is the function of CML?
to provide crew members with IP connectivity, using DNS through the GNOC
What does GNOC stand for?
Government Network Operations Center
Where are the CML Port Panels located and how many are there?
6 total:
4 in Battlestaff; 1 in Crew Rest; 1 in P20 Bay 3
Which CML Port Panel also allows connectivity to the Phased Array Antenna System?
P20 Bay3 / position 17
What are the power requirements for the CML Port Panels?
Passive
What is the function of the CML Port Panels?
to provide the operator unique keyway polarization between Red & Black ports, allowing connections directly to SIPRNET & NIPRNET
Where are the KG-175D (TACLANE-Micros) located and how many are there?
2 total
CML equipment rack, fwd lower lobe
What does TACLANE stand for?
Tactical Local Area Network Encryptor
What are the power requirements for the KG-175D (TACLANE-Micro)?
+12 VDC from KG-175D Power Supply
What is the function of the KG-175D (TACLANE-MIcro)?
to allow secure router traffic for communication
Where are the Policy Routers located and how many are there?
2 total
CML equipment rack, fwd lower lobe
What are the power requirements for the Policy Routers?
115 VAC 60 Hz from 400/60 Hz Converter
What is the function of the Policy Routers?
to perform authentication with the GNOC & set the appropriate routes to allow the KG-175D to establish a Type I encrypted tunnel to the corresponding KG-175D at the GNOC
Where are the KG-175D Power Supplies located and how many are there?
2 total
CML equipment rack, fwd lower lobe
What are the power requirements for the KG-175D Power Supplies?
115 VAC 60 Hz from 400/60 Hz Converter
What is the function of the KG-175D Power Supplies?
to convert the filtered 115 VAC, 60 Hz power from EMI Filter to +12 VDC for the KG-175D
Where is the 400/60 Hz Converter located?
E16 equipment rack, fwd lower lobe
What are the power requirements for the 400/60 Hz Converter?
115 VAC 400 Hz from PAA & CML c/bs on P67-2
What is the function of the 400/60 Hz Converter?
to convert the 115 VAC 400 Hz power to 115 VAC 60 Hz power usable for CML components & PAAS Data Receiver
Where is the PAA/CML Power Switch located?
E16 equipment rack, fwd lower lobe
What are the power requirements for the PAA/CML Power Switch?
115 VAC 400 Hz from 400/60 Hz Converter and/or the GUPS
What does GUPS stand for?
Global Uninterruptible Power Supply