Classification of Occupancy Flashcards
Group of Occupancy: Residential Dwellings
Group A
Group of Occupancy: Multiple dwelling units, residentials, hotels, apartments
Group B
Group of Occupancy: Education and Recreation
Group C
Group of Occupancy: Institutional
Group D
Group of Occupancy: Business and Mercantile
Group E
Group of Occupancy: Industrial
Group F
Group of Occupancy: Storage and Hazardous
Group G
Group of Occupancy: Assembly other than Group I
Group H
Group of Occupancy: Assembly occupant load 1000 or more
Group I
Group of Occupancy: Accessory
Group J
Dwelling Location and Lot Occupancy: Shall occupy not more than ____ of a corner lot.
90%
Dwelling Location and Lot Occupancy: Shall occupy not more than ____ of an inside lot.
80%
Dwelling Location and Lot Occupancy: Subject to the provisions on Easements of Light and View of the Civil COde of the Philippines, shall be at least ____ from the property line.
2 Meters
Every dwelling shall be constructed and arranged as to provide adequate light and ventilation as provided under _____________ of this Code.
Section 805 to 811
Sanitation: Every dwelling shall be provided with at least ___ sanitary toilet and adequate washing and drainage.
1
Foundation: Footings shall be of sufficient size and strength to support the load of the dwelling and shall be at least _____ thick.
250 mm
Foundation: Footings shall be of sufficient size and strength to support the load of the dwelling and shall be at least ______ below the surface of the ground.
600 mm
Post: Each post shall be anchored to such footing by _________________ of adequate size.
Straps and Bolts
Floor: The live load of the FIRST floor shall be at least _______ per square meter.
200 kgs
Floor: The live load of the SECOND floor shall be at least _______ per square meter.
150 kgs
The wind load for roofs shall be at least __________ per square meter for vertical projection.
120 kgs.
Stairs: Shall be at least ______ in clear width.
750 mm
Stairs: Rise of ______ and minimum run of _______.
200 mm
Entrance & Exit: There shall be at least ______ and another one for exit.
One entrance
Electrical Requirements: All electrical installations shall conform to the requirements of the ___________________.
Philippine Electrical Code
Mechanical Requirements: Mechanical systems and/or equipment installations shall be subject to the requirements of the _________________________.
Philippine Mechanical Engineering Code
Light and Ventilation: All buildings shall face a _______________________________ which has been duly approved.
Street or Public Alley or Public Street
Measurement of Site Occupancy: The measurement of site occupancy or lot occupancy shall be taken at the ________________ and shall be exclusive of courts, yards and light wells.
Ground Level
Measurement of Site Occupancy: Courts, yards and light wells shall be measured clear of all projections from the walls enclosing such wells or yards not exceeding _____ in width.
1.20 meters
Ceiling Height: For rooms with ARTIFICIAL ventilation - not less than _______ measured from floor to the ceiling.
2.40 meters
Ceiling Height: For rooms with NATURAL ventilation - not less than _______ measured from floor to the ceiling.
2.70 meters
Ceiling Height: Mezzanine Floors clear ceiling height not less than ______ above and below it.
1.80 meters
Minimum of 6.00 sqm with at least dimension of 2.00 meters.
Rooms for Human Habitations
3.00 sqm with at least dimension of 1.50 meters.
Kitchens
1.20 sqm with at least dimension of 0.90 meters.
Bath and Toilet
Eaves, canopies, awnings over required windows shall not be less than _______ from the side and rear property lines.
750 mm
Arcaded pedestrian walkways shall have a clear height of ________.
3.00 meters
Every building or usable portion there of shall have _____ number of exit.
1
Floors above the 1st storey having an occupant load of more than 10 shall not have less than _____ exits.
2
Door leaf width shall not exceed ________.
1.20 meters
Ramps shall not be less than ________ in width.
1.10 meters
Trim and hand rails shall not reduce the required width by more than ________.
100 mm
Rise shall not exceed ______.
200 mm
Stair runs shall not be less than _________.
250 mm
With standard seating, the spacing of rows of seats from back to back shall not be less than ________.
840 mm