Chapter 9 Fire Department Pumper Testing Flashcards
What tests make up preservice test? 3
manufacturers test
pump certification test
acceptance test
How often should service tests be conducted?
yearly or after extensive pump or power train repair
In order to ensure that preservice test are performed the municipality should do what?
require in apparatus that specification
most pumping fire apparatus are designed to meet requirements of ____
NFPA 1901
what is the NFPA standard for wildfire fire apparatus
NFPA 1906
what two test makeup the manufacturers test? 2
road test
hydrostatic test
while performing the manufacturers test, NFPA 1901 requires the apparatus to accelerate from __ to ___ in ___
0-35
25s
while performing manufacturers test, the apparatus must achieve a top speed of at least ___
50mph
while performing the manufacturers test, the apparatus must come to a full stop from 20 miles an hour within __
35ft
which are superior standards performance-based specifications or engineer base specifications
performance-based specifications
what does the hydrostatic test determine
whether the pump and piping can withstand normal operating pressures
NFPA 1901 requires that pump to be hydrostatic retested at ___psi for ___
250 PSI
three minutes
during the hydrostatic test what lines/valves should be open/closed/capped
fill line (tank refill), tank to pump line, bypass line valves closed discharge valves should be open and capped Intake valves should be close or capped
While the hydrostatic test determines if the pump and piping were constructed properly. the pump certification test determines what?
if the pump performs properly
what tests are performed during the certification test (6)
1 pumping test 2 pumping engine overload test 3 pressure control system test 4 priming device test 5 vacuum test 6 water tank to pump flow test
what are the conditions under which a pump certification test must be conducted 4
- must be carried out from a static supply source
- strainer and must be submerged at least 2 feet
- water may be no more than 10 feet from pump
- 20 feet of hard suction should be used
describe the pumping test 750 gpm and above capacity
100% @ 150 for 2h 70% @ 200 for 30min 50% @250 for 30min volume, discharge pressure, intake pressure, RPM recorded every 15 minutes average = rated capacity