Chapter 2 - Structural Fire Resistance and Building Classifications Flashcards

1
Q

Fire resistance determines the likelihood of ?

A

structural collapse under fire conditions

p45

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The combustible nature of a buildings _________ _______ will impact the rate of fire growth.

A

structural system

p45

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

In addition to classifying buildings by construction type, building codes classify buildings by their ?

A

occupancy

p46

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

From a fire protection standpoint, one of the most basic properties of building materials is their degree of _____ _________.

A

fire resistance

p46

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Fire resistance is a function of the properties of all materials used, including ?

A

combustibility, thermal conductivity, chemical composition, density and dimensions

p46

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The ability of a structural assembly to maintain its load-bearing capacity and structural integrity under fire conditions is called ?

A

Fire-resistance

p46

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

True or False:

Fire-resistive construction is not prone to structural failure under fire conditions?

A

True - is not prone to structural failure under fire conditions

p46

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

In the case of walls, partitions, and ceilings, fire resistivity also means the ability to act as a ?

A

a barrier to fire

p46

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Fire resistance ratings are expressed in ?

A

hours and fractions of hours

p46

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Ratings assigned to a material or an assembly after standardized testing by an independent testing organization that identifies the amount of time a material or assembly of materials will resist a typical fire as measured on a standard time-temperature curve is called ?

A

Fire Resistance Rating

p46

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

For example, a building code will typically require that columns supporting the floors in a fire resistive building have a fire resistance rating of ?

A

3 hours

p46

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The walls enclosing an exit stairwell, which may or may not be load bearing, typically must have a fire resistive rating of ?

A

1 or 2 hours to protect the stairwell

p46

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Of the three means of fire resistance determination the most commonly used method is by ?

A

laboratory test

p47

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Standard Method of Tests of Fire Endurance of Building Construction and Materials is NFPA _____ ?

A

NFPA 251

p47

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The primary means used to determine a fire resistance rating is to subject the component to be evaluated to the heat of a ?

A

standard fire in a test furnace

p47

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Normally, assemblies are not tested beyond _____ hours because this is the maximum time required by the building codes.

A

four hours

p48

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What test is the only method currently universally accepted by building codes ?

A

E-119

p49

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

When the continuity of an assembly is destroyed, it cannot function as a ?

A

fire barrier

p50

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Solid materials, such as wood blocks, used to prevent or limit vertical and horizontal spread of fire and products of combustion in hollow walls or floors, above false ceilings, in penetrations for plumbing or electrical installations, in penetrations of a fire-rated assembly, or in clock lofts and crawl spaces are called ?

A

Fire Stop

p50

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Underwriters Laboratories annually publishes a _____ _________ _________, which lists assemblies that have been tested and their fire resistance ratings.

A

Fire Resistive Directory

p51

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What standard provides the methods for calculating fire-resistance ratings that are equivalent to the results obtained from the standard fire test?

A

ASCE/SFPE 29, Standard Calculation Methods for Structural Fire Protection

p52

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Which NFPA standard is the time-temperature test that is the most commonly used method of satisfying building code requirements for structural fire resistance?

A

NFPA 251

p53

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Incapable of supporting combustion under normal circumstances is ?

A

Noncombustible

p53

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

What is the most commonly used test for determining combustibility ?

A

ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 degrees C

p54

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

Bricks, blocks, stones, and unreinforced and reinforced concrete products are called ?

A

Masonry

p54

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

With the exception of _____ ___, ______ ______, the major building classifications are further divided into two or three sub classifications.

A

Type IV, Heavy Timber

p54

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

Which NFPA standard details the requirements for each of the classifications and sub classifications of building construction ?

A

NFPA 220, Standard on Types of Building Construction

p54

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

In NFPA 220 each classification is designated by a ?

A

three-digit number code

p54

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

NFPA 220

- The first digit refers to the fire-resistance rating (in hours) of ?

A

of exterior bearing walls

p54

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

NFPA 220

- The second digit refers to the fire-resistance rating of ?

A

structural frames or columns and grinders that support loads of more than one floor

p54

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

NFPA 220

- The third digit indicates the fire-resistance rating of the ?

A

floor construction

p54

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

In Type IV construction the designation ______ is used.

A

2HH

p54

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

The highest requirements for fire resistance are for ____ ___ construction, with lesser requirements for other types of construction.

A

Type I

p54

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

In Type I or fire-resistive construction, the structural members are of ?

A

non-combustible construction that has a specified fire resistance

p55

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

An example of a noncombustible material that is not fire-resistive and must be protected to attain fire resistance is ?

A

steel

p55

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

Generally, bearing walls, columns, and beams are required to have a fire resistance of how many hours, depending on the code and the construction classification ?

A

two to four hours

p55

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

Floor construction is required to have a fire resistance of how many hours ?

A

Two or three hours

p55

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
38
Q

The roof deck and construction supporting the roof must have a fire resistance of how many hours ?

A

One to two hours

p55

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
39
Q

As a practical matter, building codes usually permit a limited use of what materials in Type I construction ?

A

combustible materials

p57

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
40
Q

The two most common methods of constructing Type I buildings are by using ?

A

reinforced concrete or a protected steel frame

p57

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
41
Q

In the case of a steel frame building, it must be remembered that unprotected steel has no ?

A

fire-resistance

p58

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
42
Q

Type II construction (noncombustible) can be either _______ or __________.

A

protected or unprotected

p58

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
43
Q

In unprotected construction, the major components are __________ and have no _____ ________.

A

noncombustible / fire resistance

p58

44
Q

An unprotected, non combustible building cannot be expected to provide what under fire conditions ?

A

structural stability

p58

45
Q

Type III construction has been commonly referred to as ?

A

“ordinary construction”

p58

46
Q

Type III construction has two sub classifications:

  • Type III A construction is required to have what fire resistive rating for interior members?
  • Type III B construction is required to have what fire resistance rating for interior member?
A

Type III A - one hour fire resistive rating
Type III B - no fire resistance requirements

p59

47
Q

Type IV construction is commonly know as ______ ______ or “_____” construction.

A

heavy-timber or “mill”

p60

48
Q

In Type IV construction the beams, columns, floors, and roofs are made of ______ or _________ wood with dimensions greater than in Type III construction.

A

solid or laminated

p60

49
Q

Type V construction is also commonly know as ?

A

wood-frame construction

p61

50
Q

In Type V construction all the major structural components are permitted to be of ?

A

combustible construction

p61

51
Q

Method for construction of wood-frame buildings. Replaced the use of heavy timber wood framing.

A

Light-Frame Construction

p62

52
Q

The terms that refer to the maximum heat that would be released if all the available fuel in the building was consumed ?

A

Fire load or fuel load

p63

53
Q

The amount of fuel within a compartment expressed in pounds per square foot obtained by dividing the amount of fuel present by the floor area is called ?

A

Fire load

p63

54
Q

Ordinary combustibles such as wood, paper, and similar materials have heats of combustion between _____ and _____ BTU per pound.

A

7000 and 8000

p63

55
Q

The fire load can be used as an estimate of the total potential _____ release or ______ _______ to which a building may be subjected if all combustibles become fully involved in fire.

A

heat / thermal energy

p63

56
Q

The International Building Code (IBC) contains how many major occupancy classifications ?

A

Ten

p64

57
Q

The IBC contains a total of how many subgroups within the 10 major occupancy classifications?

A

26 subgroups

p65

58
Q

NFPA has how many major occupancy classifications ?

A

12

p65

59
Q

Building Construction and Safety Code is NFPA ?

A

NFPA 5000

p65

60
Q

Life Safety Code is NFPA ?

A

NFPA 101

p65

61
Q

In the United States the first known fire tests were conducted in Denver, CO in _______ with subsequent tests in New York City in _______.

A

1890 / 1896

p 47

62
Q

Fire resistance:

The standard was adopted by the NFPA in ______ and has evolved as an NFPA standard ever since.

A

1917

p 47

63
Q

Test method:

The temperature in the test furnace is raised along a ______ ________.

A

time scale

p 47

64
Q

Test method:

A temperature of ______F is reached at five minutes and ______F after 30 minutes. At one hour the temperature is ______*F.

A

1000 / 1550 / 1700

p 47

65
Q

Test method:

The test results will be classified as either ?

A

load bearing or non-load bearing

p 47

66
Q

Test method:

In addition, the fire resistive ratings for floors and ceiling assemblies are developed for both _____________ and _____________ assemblies.

A

restrained and unrestrained

p 47

67
Q

Fire testing:

If a partition wall were being tested to obtain a 2-hour fire rating, the test would be stopped at two hours if ?

A

failure had not occurred

p 48

68
Q

Primary points of failure for the test are:

  • Failure to support an applied _______
  • Temperature increase on the unexposed side of wall, floor, and roof assemblies of ______ *F above ambient temperatures.
  • Passage of heat or flame through the assembly sufficient to ignite ________ waste.
  • Excess temperature on ________ members.
A
  • load
  • 250*F
  • cotton
  • steel

p 48-49

69
Q

Certain wall and partition assemblies are subjected to application of a ______ ________ to duplicate the impact and thermal shock of water that might occur during fire fighting operations.

A

hose stream

p 49

70
Q

Testing:

Fire resistance rating for test specimens, including fire doors and windows, are expressed in standard intervals such as ____, ____, or ____ minutes, ____, _____, ____, ____, or ____ hours. Thus, if a given assembly failed one hour and ten minutes into a test, it’s fire rating would be ?

A

15, 30, or 45 / 1, 1 1/2, 2, 3, or 4 / one hour

p 49

71
Q

Testing:

The test furnace used by Underwriters Laboratories, Inc, (UL) for testing beams, floor, and roof assemblies has an approximate plan dimensions of ____ X ____ feet.

A

14 X 17

p 49

72
Q

Testing:

It must be remembered that the standard time-temperature curve may not duplicate the situations encountered in ______ ______.

A

real fires

p 49

73
Q

Testing:

This test would be useful for evaluating the structural members used in such occupancies as petroleum refineries ?

A

ASTM Standard 1529, Standard Test Methods for Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies

p 49

74
Q

Fundamentally, a _______________ material is one that “in the form in which used and under the conditions anticipated, will not ignite, burn, support combustion or release flammable vapors, when subjected to fire or heat.”

A

Noncombustible

p 53-54

75
Q

Building classifications:

  • Type I, ______ __________
  • Type II, _________________ or protected ______________
  • Type III, ___________ protected (___________)
  • Type IV, Heavy _________
  • Type V, _______ frame
A
  • Fire-resistive
  • Noncombustible / Noncombustible
  • Exterior / (masonry)
  • timber
  • Wood

p 54

76
Q

NFAP 220

  • The _________ digit refers to the fire resistance rating (in hours) of exterior bearing walls
A
  • first

p 54

77
Q

NFPA 220

  • The ___________ digit refers to the fire resistance rating of structural frames or columns and girders that support loads of more than one floor.
A
  • second

p 54

78
Q

NFPA 220

  • The _________ digit indicates the fire resistance rating of the floor construction.
A
  • third

p 54

79
Q

In ______ ___ or ______ __________ construction, the structural members are of non-combustible construction that has a specific fire resistance.

A

Type I or fire resistive

p 55

80
Q

Type I

Interior partitions enclosing stairwells and corridors are required to be fire-resistive as specified by local code, usually ______ or ______ hours.

A

one or two

p 55

81
Q

Type I

The fire-resistive compartmentation provided by __________ and _______ tends to retard the spread of fire through a building.

A

partitions and floors

p 57

82
Q

___________ is an inherently non combustible material with good thermal insulating properties.

A

Concrete

p 57

83
Q

Type I

When steel is used in fire-resistive design it must be protected by an ____________ ____________.

A

insulating material

p 58

84
Q

Type II

The use of unprotected ________ is the most common characteristic of unprotected, non combustible construction.

A

steel

p 58

85
Q

Type II

In II-A construction the structural components are required to have _____-_______ fire resistance.

A

one-hour

p 58

86
Q

Type II

In II-B construction structural components are _____________.

A

unprotected

p 58

87
Q

Type III construction is frequently constructed with exterior walls of __________, but from a technical standpoint any non combustible material with the required ______ __________ can be used for the exterior walls.

A

masonry / fire resistance

p 58

88
Q

Type III

Interior structural members including walls, columns, beams, floors, and roofs are permitted to be partially or wholly _____________.

A

combustible

p 58

89
Q

Type III

The interior structural members of Type III construction may be ___________ or ______________.

A

protected or unprotected

p 59

90
Q

When structural components of Type III construction are required to have a fire rating they can be protected by several means. Probably the most common are the use of _________ in older buildings and ________ ________ in newer buildings.

A

plaster / gypsum board

p 59

91
Q

The dimensions of the wood used in Type III construction are permitted to be ___________ than those required in Type IV construction.

A

smaller

p 59

92
Q

There are two important distinctions between Type III and Type IV construction:

  • In Type IV construction the beams, columns, floors and roofs are made of ________ or _____________ wood with dimensions greater than in Type III construction.
  • Concealed spaces are not permitted between structural members in ________ _____ construction.
A
  • solid or laminated
  • Type IV

p 60

93
Q

The greater ________ of the heavy timber components provide greater structural endurance under fire conditions than the structural members used in Type _____ buildings.

A

mass / III

p 61

94
Q

The basic method of construction in a Type V building consists of using a ______ ________ to provide the primary structural support.

A

wood frame

p 61

95
Q

Many Type V structures are required to have a ____ hour fire resistance for the structural members. This is typically accomplished by protecting the combustible frame members with __________ or fire rated _________ board.

A

1 / plaster / gypsum

p 61

96
Q

A fundamental problem posed by Type V construction is the creation of combustible _____________ ______ and ___________ more extensive than are found in Type III construction.

A

concealed voids / channels

p 62

97
Q

Several different methods can be used to construct a Type V building. In modern practice, wood frame buildings are most often constructed using a method known as _______-________ construction.

A

light-frame

p 62

98
Q

Mixed construction:

For example, in some jurisdictions it is permissible to have Type ____ construction over Type ____ construction up to a height of _____ feet.

A

V / I / 70

p 62

99
Q

A three story parking garage with Type V construction above is an example of ?

A

Mixed construction

p 62

100
Q

Building with _____________ structural components (Types ____, ____, and ____) have an inherently greater fire load than Types ____ or _____ because the structural framing materials contribute a significant amount of fuel to a fire.

A

combustible / III, IV, and V / I or II

p 63

101
Q

A fire load does not translate into an equivalent ___________ load.

A

structural load

p 63

102
Q

Building codes classify buildings according to their ____________ as well as their construction type.

A

occupancy

p 63

103
Q

The occupancy classifications assign building occupancies into groups with broadly _________ ______ ________.

A

similar fire risks

p 63

104
Q

Mixed occupancies:

Building codes may require fire-resistive ___________ between various occupancies.

A

separations

p 66

105
Q

All building codes classify buildings by construction type. These classifications are based on two attributes of building construction: ____ ________ and __________.

A

fire resistance and combustibility

p45