PASS stands for?
Personal alert safety system
6 scba major components
- cylinder and cylinder valve
- Harness, back frame, dual ebss with 3 ft of hose, stage rescue loop, ric/uac
- Pressure reducer assembly
- Breaking regulator - vibralert alarm, purge valve, air saver switch, heads up display
- Pak alert se distress alarm - sensor module with pak tracker locator transmitter, control console, remote pressure gauge.
- Face piece - AV 2000
How many feet is the ebss hose?
3 ft
Composition and pressure of the Scott air pak fifty bottle
Aluminum shell over wrapped with carbon fiber reinforced with epoxy resin.
What is the psi for Scott air pak fifty bottle, how long will it last and how many cubic feet of air is this?
4500 psi, 60 minutes, and 87 cu feet
Who regulates the testing of the scba bottles and how often are they tested
DOT, every 5 years
What is the nominal weight of the scba bottle and the weight when installed as the air pak assembly?
17.1, 26.1 lbs
This does not include the quick connect with hud, the ebss, or the pak alert with pak tracker
The components of the cylinder
Cylinder valve assembly consisting of a shut off valve, a safety relief device (copper frangible disk), and a pressure gauge
How many bleed holes are on the cylinder valve and what is their purpose?
2 - to allow air to vent should the low pressure system be attached to the high pressure cylinder
What is the harness and bac frame assembly constructed of?
Stamped aluminum
What are the pak straps made of
Kevlar
What is the pressure the primary reducing circuit reduces the high pressure air to?
100 psi
When the air pressure in the cylinder falls to ____ and _____, the primary pressure reducing circuit fails in the ____position, a transfer valve opens allowing he secondary pressure reducing circuit to function. It reduces the pressure to ____psi. The ____psi supplied by the secondary circuit activates the vibralert.
1000, 1200, closed, 150, 50.
The over pressure relief valve on the manifold is set to ____psi. This protects the low pressure hose and regulator should the primary reducing circuit fail in the _____position
225, open
Vibralert warns the user that there is how much pressure left in the cylinder?
25%, 1000-1200
6 components of the regulator
- Air saver switch
- Spray bar
- Spring clip
- Purge valve
- Vibralert alarm
- Heads up display
What is the pressure above atmospheric pressure inside r face piece?
0.036-0.054 psi
How many homes in the spray bar?
9
What is he normal position of the purge valve? What direction is it turned to operate it?
12 o clock, counter clockwise
How many cu ft or liters of air can the purge valve flow?
4.4 cu ft or 125 liters per minute
Vibralert will activate under these three conditions?
- Less than 25% air
- Primary reducing circuit failed, secondary in operation
- Primary reducing circuit failed open, air at 225 psi entered manifold causing loud escaping air sound
When the pak is turned on, how many lights light up and for how long?
5 lights for 20 seconds