Chapter 19 Heat Exchangers for Refrigeration Systems Flashcards
1. Based on how they operate one of the basic types of evaporator is the \_\_\_\_\_ evaporator. A. Dry/indirect expansion B. Evaporative C. Aerial D. Cold expansion E. Flooded
E. Flooded
2. One of the general types of condensers is the \_\_\_\_\_ condenser. A. Flooded B. Dry C. Direct expansion D. Bare tube E. Evaporative
E. Evaporative
3. One of the general types of condensers is the \_\_\_\_\_ condenser. A. Flooded B. Dry C. Air-cooled D. Direct expansion E. Bare tube
C. Air-cooled
4. One of the main heat exchangers used in the compression refrigeration system is the: A. Evaporator B. Compressor C. Absorber D. Regenerator E. Cooling tower
A. Evaporator
5. The shell and tube evaporator is also known as a: A. Cooler B. Chiller C. Condenser D. Evaporator E. Heat exchanger
B. Chiller
- The air-cooled condenser has the refrigerant vapour flowing _____ while the
cooling air is circulated _____.
A. Through finned tubes, around the outside of the tubes
B. Around the outside of the tubes, through finned tubes
C. Through bare tubes, around the outside of the tubes
D. Through finned tubes, around the outside of the bare tubes
E. Around the outside of the tubes, through bare tubes
A. Through finned tubes, around the outside of the tubes
- The finned tube evaporator is basically a bare tube evaporator coil with fins
attached to it by crimping or bonding to form a/an:
A. Increased heat exchange surface area
B. Decreased heat exchange surface area
C. Increased temperature exchange surface area
D. Decreased temperature exchange surface area
E. Increased heat exchange volume
A. Increased heat exchange surface area
8. Evaporative condensers are favored in locations where it is necessary to conserve on: A. Power B. Space C. Water D. Noise E. Air
C. Water
- A proper chemical treatment program for evaporative condensers includes a/an:
A. Oxygen scavenger
B. Scale producer
C. Precipitation agent
D. Sludge conditioner
E. Anti-foaming agent to prevent turbulence from creating foam in the sump
E. Anti-foaming agent to prevent turbulence from creating foam in the sump
10.In the direct-expansion shell and tube evaporator, the liquid refrigerant is: A. In the shell B. Around the tubes C. In the tubes D. Over the tubes E. Under the shell
C. In the tubes
11.The function of the refrigeration condenser is to cool the superheated refrigerant
vapour until it _____ and then becomes sub-cooled.
A. Condenses to a vapour
B. Evaporates to a liquid
C. Evaporates to a vapour
D. Freezes
E. Condenses to a liquid
E. Condenses to a liquid
12.One of the basic designs of water-cooled condensers is the \_\_\_\_\_ condenser: A. Flooded B. Double tube C. Direct expansion D. Bare tube E. Evaporative
B. Double tube
13.The shell and coil condenser consists of a horizontal or vertical steel shell which
contains a coiled tube, either bare or finned, through which the _____ circulates.
A. Cooling water
B. Refrigerant vapour
C. Refrigerant liquid
D. Cooling air
E. Condensate
A. Cooling water
14.Bare tube evaporators are used when the space temperature is maintained below: A. 15°C (59°F) B. 10°C (50°F) C. 5°C (41°F) D. 1°C (34°F) E. 20°C (68°F)
D. 1°C (34°F)
15.The shell and tube condenser is fitted with: A. End plates B. Water boxes C. Dry boxes D. Wet boxes E. Water plates
B. Water boxes