If the specification does not state a required standard, then it is good practice to chose a standard, such as _______, whose guidelines are broadly accepted in the coatings industry.

A

SSPC-PA 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Common errors that can produce inaccurate readings when using a Wet Film Thickness gauge include:

A

Using a damaged gauge

Dragging a gauge through wet coating (this causes a false high reading)

Placing the gauge along the circumference of a pipe or curved surface, rather than along the longitudinal axis, when measureing WFT on pipes or curved surfaces

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Common errors that may produce inaccurate readings when using a Dial-Type Magnetic Pull-Off DFT Gauge include:

A
  • Failure to determine the BMR
  • Rotating the dial too fast when taking measurements
  • Taking measurements too close to the edge or on vibrating surfaces
  • Measuring dirty, tacky, or soft films
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Name a few of the most commonly used standards that govern DFT measurement:

A
  • SSPC-PA 2
  • ASTM D 7091
  • ISO 19840, 2808, 2178
  • IMO Resolution MSC.216 (82), Annex 3
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

SSPC-PA 2 requires 5 spot measurements (a minimum of three readings per spot are needed to account for surface irregularities within the ______ circle of the spot.

A

4 cm [1.5 in.]