Chapter 15: Fire Protection Systems Flashcards
Fixed _____ sprays are designed specifically to provide optimum control, extinguishment, or exposure protection for special fire protection problems.
Select one:
a.
Foam
b.
Gas
c.
Water
d.
Purple-K
e.
Oil
c.
Water
The procedure for the first person on the scene of a fire should:
1. Sound the fire alarm.
2. Complete a risk assessment of the situation.
3. Attempt to extinguish or control the fire.
4. Turn away and leave the fire.
Select one:
a.
1, 4
b.
2, 3
c.
1, 3
d.
1, 2, 4
e.
1, 2, 3
e.
1, 2, 3
A2C15Q03 The water pressure at the topmost outlet of each standpipe should not be less than _________ with a flow rate in the system of 32 litres per second (L/s).
Select one:
a.
650 kPa
b.
450 kPa
c.
450 Pa
d.
700 kPa
b.
450 kPa
Heat detectors are generally located on or near the:
Select one:
a.
Floor
b.
Walls
c.
Ceiling
d.
Roof top
e.
Exits
c.
Ceiling
A2C15Q04 The dry pipe system is the design used in environments where the temperature could become less than 4°C. The piping normally contains air under pressure, at a maximum of _______.
Select one:
a.
275 kPa
b.
450 kPa
c.
275 Pa
d.
450 Pa
a.
275 kPa
A2C15Q02 The rate of rise detector will function when the rate of temperature increase exceeds a predetermined value, typically ______________________.
Select one:
a.
Around 2°C to 4°C per second
b.
Around 7°C to 8°C per minute
c.
Around 7°C to 8°C per second
d.
Around 5°C to 12°C per minute
b.
Around 7°C to 8°C per minute
________ was developed at the U.S. Naval Research Laboratory primarily to provide very rapid fire extinguishment or knockdown capabilities.
Select one:
a.
ARC
b.
PFC
c.
DFFG
d.
Purple-K
e.
NFPA
d.
Purple-K
One way to detect freezing in a hydrant is:
Select one:
a.
Open the hydrant fully and listen for water
b.
Lower a weight on a stout string into the hydrant to see if it strikes ice or water
c.
Pressurize the hydrant with gas
d.
Strike the hydrant with a hammer and listen for the ringing sound
e.
Feel the temperature of the metal
b.
Lower a weight on a stout string into the hydrant to see if it strikes ice or water
A2C15Q09 Emergency response procedures are established to ensure the immediate and competent handling of emergencies involving any unplanned occurrences, such as accidents or property threatening events like __________.
Select one:
a.
Explosions
b.
Fires
c.
Earthquakes
d.
Riots
b.
Fires
A central foam distributing system for a process building consists of an enclosure that houses a foam concentrate supply tank and a _____ device.
Select one:
a.
Dividing
b.
Mixing
c.
Separating
d.
Floating
e.
Proportioning
e.
Proportioning
When a fire pump system is installed, what are the minimum requirements that must be followed?
Select one:
a.
The advice of the engineer who is designed the system
b.
Company’s policy to protect equipment and employees
c.
Insurance underwriters’ recommendations
d.
NFPA Standard 20
e.
Local fire marshall’s recommendations
d.
NFPA Standard 20
For average conditions, hydrants are normally placed about _____ from buildings.
Select one:
a.
10 m
b.
12 m
c.
15 m
d.
25 m
e.
30 m
b.
12 m
A2C15Q08 When supplied with a foam solution, sprinkler system piping grids that are equipped with foam-water nozzles generate air-foam in essentially the same sprinkler pattern as when water is discharged from the same nozzle. This dual capability affords the system with __________ extinguishment ability.
Select one:
a.
Class B and C
b.
Class A and B
c.
Class C and D
d.
Class A and C
b.
Class A and B
Which of the following extinguishers would ordinarily be used to combat a Class C fire?
1. Carbon dioxide
2. Foam
3. Dry chemical
4. Water
Select one:
a.
1, 2
b.
1, 3
c.
2, 3
d.
1, 4
e.
3, 4
b.
1, 3
Which of the following could have a Class C fire?
Select one:
a.
Lumber pile
b.
Generator coils
c.
Coal pile
d.
Fuel tank
e.
Paint can
b.
Generator coils