Chapter 13: Distributed and Logic Control Flashcards
A2C13Q15 RTUs are ________________.
Select one:
a.
Remote terminal units
b.
Located in central control rooms
c.
Restricted telemetry units
d.
Remote telephone users
a.
Remote terminal units
A2C13Q10 What can an operator do to stabilize a process?
Select one:
a.
Increase the control output signal
b.
Lower the set point
c.
Switch control from automatic to manual
d.
Switch control from manual to automatic
c.
Switch control from automatic to manual
A2C13Q52 Each input and each output is identified with ____________ so they can be identified and addressed by the PLC program.
Select one:
a.
Logical expressions
b.
Code names
c.
Comments
d.
Tag names
d.
Tag names
A2C13Q62 Function block diagrams are easier to read because each function block ______________.
Select one:
a.
Controls an entire process
b.
Replaces multiple rungs of a ladder diagram
c.
Is programmed in plain English
d.
Has only a single input and a single output
b.
Replaces multiple rungs of a ladder diagram
A2C13Q30 What are panel-mounted alarm annunciators best used for?
Select one:
a.
False alarms
b.
First out alarms
c.
Minor alarms
d.
Critical alarms
d.
Critical alarms
A2C13Q36 Before a steam boiler can be fired, all of the permissives must be satisfied. What is the binary logic for this example?
Select one:
a.
OR
b.
AND
c.
IF
d.
NOT
b.
AND
A2C13Q48 Which of the following is not part of a ladder diagram?
Select one:
a.
Rails
b.
Outputs
c.
Rungs
d.
Feet
d.
Feet
PLCs can do which of the following?
1. Control only a single process.
2. Control multiple continuous processes.
3. Be used in SCADA systems.
4. Control only one process at a time.
Select one:
a.
1, 2
b.
2, 3
c.
3, 4
d.
1, 3
e.
1, 4
b.
2, 3
A2C13Q25 What happens when a HI-HI or LO-LO alarm causes a trip?
Select one:
a.
The operator must manually shut down all process equipment in the correct order
b.
The operator must hit the emergency stop button to stop the process
c.
The affected process equipment immediately stops
d.
The control system begins a controlled, fully automatic, sequential shutdown
d.
The control system begins a controlled, fully automatic, sequential shutdown
A2C13Q21 On the graphic display of an operator interface unit, which colour is typically used in the power generation industry to indicate a motor that is running?
Select one:
a.
Green
b.
Yellow
c.
Blinking
d.
Red
d.
Red
A2C13Q32 What does a NOT logic gate have?
Select one:
a.
Two binary inputs and two binary outputs
b.
Two binary inputs and one binary output
c.
One binary input and two binary outputs
d.
One binary input and one binary output
d.
One binary input and one binary output
A2C13Q38 How many rows does the truth table for a NOT gate have?
Select one:
a.
3
b.
2
c.
4
d.
1
b.
2
A2C13Q13 ________________ are more vulnerable to viruses and malicious malware.
Select one:
a.
HMIs
b.
SCADA systems
c.
PLCs
d.
DCSs
b.
SCADA systems
A2C13Q07 In a DCS, where are ADCs and DACs located?
Select one:
a.
In the discrete I/O modules
b.
Digital I/O modules
c.
Analog I/O modules
d.
Controller microprocessor
c.
Analog I/O modules
A2C13Q53 Unlike an electrical wiring schematic, a ladder diagram shows the flow of what?
Select one:
a.
Control logic
b.
Matter
c.
Electric current
d.
Energy
a.
Control logic