Ch2 Size Up Flashcards
COAL WAS WEALTH
Construction
Occupancy
Apparatus and personnel
Life hazard
Water supply
Auxiliary appliances
Street conditions
Weather Exposures Area and height Location and extent of fire Time Haz-mat
Nearly 80% of all civilian fire deaths occur in ___________ buildings.
Residential
A key indicator of the likelihood of structural collapse
Elapsed Burn Time
The ONLY two types of construction to which the 20-minute rule applies
Class 3 and Class 5
When does the clock start for the 20-minute rule?
When the fire has reached flashover and begun to attack the structural elements
Three problematic locations for fire
- Top floor of most Type III and framed structures
- Below grade
- Beyond reach of ladders
Often the best way to prevent fire extension
Put out the fire
Strategy and tactics should be based on…
Available resources
Units used for fuel load
lb/sq ft
Btu’s given off by each pound of ordinary combustibles when totally consumed
7,000-10,000 Btu
Btu absorbed by one gallon of water when heated from 70 degrees to steam
9,275 Btu
Units used for fire flow
Gallons per minute - gpm
1 gallon of water will cool how much fuel?
Approximately 5lb
Suggested flow rates for residential, commercial, and heavy industrial occupancies
- Residential = 0.15gpm/sq ft
- Commercial = 0.35gpm/sq ft
- Heavy Industrial = 0.5-0.6gpm/sq ft