(CH)- Boric Acid Concentrator Flashcards

1
Q

What is the purpose of the BAC feed valve, CH-287?

A

A modulated fail-closed valve which maintains a flash tank Setpoint level via the flash tank level indicator controller LIC-287

The setpoint corresponds to a predetermined flash tank level and is dialed into LIC-287 at the control panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What’s included in the BAC concentrate loop?

A

The concentrate pumps, concentrate heater, flash tank, interconnecting piping, valves, instrumentation and controls

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Concerning the BAC Concentrate Loop, what would you expect to see operating during normal ops?

A

Both of the 1500 gpm concentrate pumps operate in parallel to provide the 3000 gpm process fluid circulation through the heater into the flash tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

In regards to the BAC Concentrator, what effect on its operation will occur upon a loss of either circulating pump?

A

Will not cause a concentrator shutdown or loss in processing capacity, but continued single pump operation will increase the tendency of the heater to foul

Two check valves are installed downstream of each pump to preclude backflow during single pump operation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Concerning the check valves downstream of the BAC Concentrate circulating pumps, why is there a 3/8” perforation?

A

To provide limited concentrate recirculation during single pump operation, which will keep the non-operating pump sufficiently heated to prevent precipitation of solids

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Approximately how hot will the concentrate be when it enters the flash tank in the BAC system?

A

240F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What system provides cooling to the BAC Concentrate cooler?

A

Nuclear Cooling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Why do we backwash two of the three demisters in the BAC flash tank?

A

Assists in removing any boric acid or other impurities which are entrained in the vapor stream

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How can I remove tritium from the BAC skid?

A

Distillate steam form the Vapor Separator may be directly discharged to plant piping through CHN-V282 and out the plant vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What would be the adverse effect of using insignificant flow from the steam vent in the BAC system?

A

Will starve the distillate system and require the use of RMW to supplement distillate water for Distillate Flush functions on the skid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the purpose of the CVCS Holdup Tank and what is its capacity?

A

Stores all recoverable Reactor Coolant and provides the NPSH required for operation of the Holdup Pumps

holdup capacity for recycle waste water produced during refueling and power ops

hold up capacity for drains, reliefs and leakage collected in the RDT and EDT

550,000 gallon capacity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What temperature is maintained in the CVCS Holdup Tank and how is it maintained?

A

Maintained above 60F by two sets of redundant 25 kW heaters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

At what level in the CVCS Holdup Tank will the BAC be used to begin processing?

A

17 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where does the CVCS Holdup tank vent to? Where is this tank located?

A

Fuel Building Ventilation

RCA yard next to RMWT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the basis of the CVCS Holdup Tank capacity?

A

Designed to store all recoverable water from back-to-back cold shutdowns to 5% subcritical and subsequent startup at 90% core life

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the purpose of the CVCS Holdup Tank Pumps?

A

Two pumps to transfer the contents of the CVCS Holdup tank to the BAC

recirculate the CVCS holdup tank contents

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What is the purpose of the recirculation line on the CVCS Holdup Tank pumps?

A

Recirculation line goes back to the HUT to prevent dead heading the pump when the BAC inlet valve cycles

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What is the capacity of the CVCS Holdup Tank Pumps?

A

50 gpm each

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Where are the CVCS Holdup tank Pumps operated and how are they interlocked?

A

Controlled manually at the CVCS hold up tank pump room next to the HUT

Interlocked to prevent both pumps from operating simultaneously

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

What would stop the CVCS Holdup tank Pumps automatically?

A

Lo-lo CVCS holdup tank level

High BAC level

Diversion of letdown flow to the Pre-Holdup Ion Exchanger when the contents are being purified

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What is the purpose of the Boric Acid Concentrator?

A

Processes relatively good quality equipment drain type inputs stored in the CVCS Holdup tank by heating and vaporizing the fluid

increases the boron concentration of the BAC bottoms to a level greater than the RWT, where the borated water is normally sent for reuse

22
Q

If one of the Boric Acid Concentrator pumps becomes inoperable, why will the BAC be secured when the batch is completed?

A

Because continued operation can cause heater fouling

23
Q

How are the BAC pumps protected from cavitation?

A

By the flash tank lo-lo alarm/cutout

24
Q

What is the heat source of the Boric Acid Concentrator Heater? Where does that source go to after the heater?

A

Aux Steam

Steam condensate is returned to the Auxiliary Steam Condensate Receiver Tank

25
Q

Where is the BAC heater located?

A

In the BAC room on the 120’ of the Radwaste building

26
Q

What is the purpose of the BAC flash tank?

A

Tank is at a reduced pressure that allows the contents of the BAC to boil

water vapor is removed as steam

27
Q

What takes suction off the BAC flash tank? Where is the flash tank located?

A

Concentrator pumps

BAC room 120’ RW building

28
Q

Concerning the BAC, what outlet temperature is maintained by the Concentrate Cooler and why?

A

175F to prevent solidification of boron in RWT piping when the concentrate outlet valve opens

29
Q

Concerning the BAC, how much of the Concentrate Cooler outlet recirculates back to the suction of the Concentrator Pumps? Where is the cooler located?

A

5 gpm to provide an indication of density through DT-295

BAC room

30
Q

Regarding the BAC, what does the Vapor Separator consist of? What cleans them? What happens when there is a high D/P?

A

Three layers of mesh pads that act as demisters of entrained liquids

spray nozzles

operator opens a valve and distillate produced at the skid flushes the bottom two pads

31
Q

Concerning the BAC, what is the maximum vapor release flowrate from the Separator? Where does the dry vapor go when leaving the vapor separator?

A

9000 lb/hr or as the effluent release permit allows

vapor condenser and plant vent

32
Q

Concerning the BAC, what is the purpose of the Vapor Condenser?

A

Uses Nuclear Cooling water to remove thermal energy from the vapor, converting the vapor back to the distillate, which in turn controls system pressure

33
Q

In regards to the Vapor condenser, what effect does more or less cooling water have on the BAC system?

A

More cooling water lowers system pressure, less cooling water allows system pressure to rise

34
Q

Regarding the BAC vapor condenser, when is PCV-993, cooler vent, fully open? what is sent through this flow path? Where is the vapor condenser located?

A

At 6 psig

non condensable gases

BAC room

35
Q

During shutdown conditions, what is the purpose of the Nitrogen connection in the BAC system?

A

Supplies nitrogen at 2-3 psig to prevent pulling an excessive vacuum during cooldown and to inhibit corrosion

36
Q

What is the purpose of the BAC Distillate Pumps? When do they start?

A

Provide flow from the Vapor condenser to the Distillate Cooler through a conductivity cell and then to the BAC condensate ion exchangers and RMWT, flush lines for the vapor separator and seal water for the BAC pumps

when there is sufficient level in the vapor condenser

37
Q

What is the purpose of the BAC Distillate cooler? Location?

A

Removes heat from the distillate to protect the resin in the Ion Exchanger

BAC room

38
Q

What is the maximum outlet temperature of the Distillate Cooler in the BAC system? What is the hi alarm set point?

A

130F

150F

39
Q

What is the purpose of the BAC Concentrate Transfer Pumps? Capacity? Location?

A

Provide flow from the heater through the Concentrate Coolers to one of the following locations: CVCS Holdup tank, LRS Concentrate Monitor Tanks, RWT

25 gpm

BAC room

40
Q

What is the purpose of the Boric acid reclamation system?

A

when the contents of the CVCS HUT need to be processed.

processing by the BAC concentrates the boron so that we can reuse the water in the RWT

41
Q

In the BAC, a portion of the vapor produced is removed as distillate release which is sent to the plant vent. Where does the rest of the vapor go?

A

condensed and cooled for pump seals and flash tank level instrumentation

the bulk of the remaining condensed liquid is sent back to the BAC skid

42
Q

When the boron concentration of the CVCS hold up tank is sufficient, where are its contents sent to?

A

RWT

43
Q

Normally, the BAC concentrates are sent to the CVCS holdup tank. Where else can they be sent?

A

LR concentrate monitor tanks for disposal

44
Q

What is needed in order to release BAC steam vapor to the plant vent?

A

release permit from the effluents group

45
Q

Where is the BAC located?

A

120’ RW building

46
Q

What is the purpose of the BAC concentrator pumps? Capacity? location?

A

provide process fluid through the BAC heater into the flash tank

50% at 1500 gpm each

120’ RW building

47
Q

What is the purpose of the BAC pump discharge check valves?

A

prevent substantial back flow during single pump operation

3/8” hole in the check valve to allow limited backflow, preventing boric acid solidification in the pump

48
Q

What is the capacity of the BAC distillate pumps? What provides flushing and seal water flow to the mechanical seals? location?

A

25 gpm each

distillate flow through a separate line

BAC room

49
Q

What side of the BAC concentrate heater is the AS steam flow admitted to?

A

shell side

50
Q

What is the BAC flash tank equipped with for a 60 psig relief?

A

rupture disk

51
Q

What side of the BAC concentrate cooler is the nuclear cooling water flow admitted to?

A

shell side