Ch. 1 General Collapse Information Flashcards
What are the 4 factors that will increase the number of burning bldg. collapses?
LAAF
- Age of the Bldg.
- Abandonment
- Lightweight construction
- FAULTY RENOVATIONS NEW
- LAAF
Unprotected lightweight steel bar joist will fail when exposed to fire for how many minutes?
Unprotected lightweight steel bar joist will fail when exposed to fire for 5-10 minutes
The perimeter of a burning bldg. is a dangerous area because of bldg. collapse and falling objects. As soon as a firefighting task is complete at the perimeter of a burning bldg. the FF’s should either do what 2 things?
Enter the Bldg. or withdraw from the danger zone.
What is the definition of a structural collapse?
When any part of the bldg. falls, NO MATTER HOW SMALL, as a result of FIRE.
What is the definition of a falling object?
Any object, OTHER THAN THE STRUCTURE, that falls, is thrown, or knocked loose from a burning Bldg.
(General Information)
The difference between a glass window being a collapse or a falling object.
- Glass falling from a window because the frame was heated and distorted by fire is a COLLAPSE.
- Glass broken by a FF venting a window is a FALLING OBJECT, and is the most common falling object at a fire.
When overhauling do not throw objects out a window unless you have permission from the IC and also have what?
A FF outside to clear the area of civilians and act as a guard
When trimming broken glass from a window, all shards should be knocked to the __________ of the Bldg.
Fill in the Blank
INSIDE of the Bldg.
Which 4 parts of the Bldg. are most likely to collapse and kill FF’s (in hierarchy order)?
- Floors
- Roofs
- Walls
- Ceilings
- Floors Really Will Collapse*