Casualty Power Flashcards

1
Q

What is casualty power?

A

Makes temporary power connections if the permanently installed ships service and emergency distribution cables are damaged.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the purpose of casualty power?

A

To keep the ship afloat and get out of a danger area, supplying power to vital pieces of equipment.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are portable welding sets and portable submersible pump outlets rated at?

A

450 volts / 25 amperes / 3 phase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

While casualty power is ran by the electricians onboard a cutter, who is ultimately responsible to ensure that the system is ready to be energized and directs that such action to be taken?

A

DCA (Damage Control Assistant)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Where total capacity of the generators supplying a switchboard is greater then _______ kw, two vertical port risers and 2 vertical starboard riser are provided.

A

500

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Portable cable has a rating of ____ amperes and a casualty power application has a rating of ____ amperes?

A

93 and 200

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The current system used for phase identification for casualty power is similar to the old method with what difference?

A

Instead of cotton cords it uses O-Rings and shrink tubing.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Megger readings of casualty power cables should be taken?

A

Annually

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

NSTM Chapter ____ is used for making repairs to cable?

A

320

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the end fitting on casualty power cables that help prevent fraying?

A

Copper Ferrule

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Each Emergency switchboard, ship’s service switchboard, and interior communications switchboard having a 450 volt 60 Hz is provided through a ________ circuit breaker.

A

AQB-LF

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Casualty power cables are stowed in __________________, in lengths of _____ ft equal to approximately _____% and no longer then ____ft?

A

Damage Repair Lockers
150
25
600

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Casualty power tags provide what information?

A

Location of what storage rack and the length in feet.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Permanently installed cables which provide vertical runs from generator spaces to the horizontal cable runs in casualty power system are called?

A

Risers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly