Carbon Monoxide Response Flashcards
CO
We are there to ________, ________, and ___________.
Advise occupants of our findings
Assist occupants with exiting
Open windows and doors for ventilation
CO response - dispatchers
No symptoms __________
Symptoms _____________
Dispatch engine company
Dispatch engine company and EMS units
IDLH and specific gravity of CO
1500 ppm
0.967
Levels as low as _________ have been known to cause __________________
2-3 COHb
Acute and chronic health effects in elderly, children, and predisposed
CO concentration vs time of exposure to reach 10 COHb
100 ppm =
200 ppm =
400 ppm =
90 min
35 min
15 min
CO
Primary concern is ______________
Safety of firefighting and EMS personnel
If there is ___________________ in a building (______________), no entry is to be made by personnel without full protective clothing and an operating SCBA.
Any reason to suspect the presence of CO
Symptomatic victims or gas monitor detects CO at entry point
Response
First priority is to ________________________.
Determine if there are any carbon monoxide illnesses related to this incident.
Once medical aid is provided, engine company should: (4)
PPE/SCBA SOP followed
Gas monitor zeroed before entry/away from CO generating source
Take FIRST reading just outside structure and document on Fire Company checklist
Take SECOND reading just inside structure and record on Fire Company Checklist
SAFD investigating CO problem. We are not there _____________.
To repair the problem
Second reading just inside the structure
If there is a reading of _________ or there is a _____________, shutdown gas to the occupancy, open windows and doors and ____________________.
OR
Any reading of ___________ requires immediate evacuation with NO re-entry allowed.
35 ppm or more.
Rise of 10 ppm or more from the outside air reading.
Call CPS, immediately evac residents.
100 ppm or more
After readings
Wait __________ and take another entry point reading.
If levels have dropped below _______, continue to ventilate and proceed with a short-term evaluation.
If levels are ___________ in any area being evaluated after _______ of ventilation, re-entry will __________.
5-10 minutes
100 ppm
Still over 100 ppm, 10 minutes
Will NOT be made
If no reading above _____ or an increase of ______ over outside reading, take readings in ______________.
35 ppm, 10 ppm
All of the rooms and record
If able to locate CO producing item, __________.
If unable to locate source, ________________.
Inform owner/occupants of findings as soon as possible and complete _________.
Owner/occupant informed so can be corrected
Contact CPS and cut off main gas to occupancy
Notice of Findings form