Carbon Monoxide Response Flashcards

1
Q

CO

We are there to ________, ________, and ___________.

A

Advise occupants of our findings
Assist occupants with exiting
Open windows and doors for ventilation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

CO response - dispatchers
No symptoms __________
Symptoms _____________

A

Dispatch engine company

Dispatch engine company and EMS units

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

IDLH and specific gravity of CO

A

1500 ppm

0.967

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Levels as low as _________ have been known to cause __________________

A

2-3 COHb

Acute and chronic health effects in elderly, children, and predisposed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

CO concentration vs time of exposure to reach 10 COHb

100 ppm =
200 ppm =
400 ppm =

A

90 min
35 min
15 min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

CO

Primary concern is ______________

A

Safety of firefighting and EMS personnel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

If there is ___________________ in a building (______________), no entry is to be made by personnel without full protective clothing and an operating SCBA.

A

Any reason to suspect the presence of CO

Symptomatic victims or gas monitor detects CO at entry point

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Response

First priority is to ________________________.

A

Determine if there are any carbon monoxide illnesses related to this incident.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Once medical aid is provided, engine company should: (4)

A

PPE/SCBA SOP followed
Gas monitor zeroed before entry/away from CO generating source
Take FIRST reading just outside structure and document on Fire Company checklist
Take SECOND reading just inside structure and record on Fire Company Checklist

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

SAFD investigating CO problem. We are not there _____________.

A

To repair the problem

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Second reading just inside the structure
If there is a reading of _________ or there is a _____________, shutdown gas to the occupancy, open windows and doors and ____________________.

OR

Any reading of ___________ requires immediate evacuation with NO re-entry allowed.

A

35 ppm or more.
Rise of 10 ppm or more from the outside air reading.
Call CPS, immediately evac residents.

100 ppm or more

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

After readings
Wait __________ and take another entry point reading.
If levels have dropped below _______, continue to ventilate and proceed with a short-term evaluation.

If levels are ___________ in any area being evaluated after _______ of ventilation, re-entry will __________.

A

5-10 minutes

100 ppm

Still over 100 ppm, 10 minutes
Will NOT be made

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

If no reading above _____ or an increase of ______ over outside reading, take readings in ______________.

A

35 ppm, 10 ppm

All of the rooms and record

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

If able to locate CO producing item, __________.
If unable to locate source, ________________.

Inform owner/occupants of findings as soon as possible and complete _________.

A

Owner/occupant informed so can be corrected
Contact CPS and cut off main gas to occupancy

Notice of Findings form

How well did you know this?
1
Not at all
2
3
4
5
Perfectly