In a typical high pressure-pneumatic system, if the moisture separator does not vent accumulated water when the compressor shut down, a likely cause is a
malfunctioning solenoid dump valve
Which section of a turbine engine provides high pressure bleed air to an air cycle machine for pressurization and air-conditioning?
Low or high pressure compressor
At which component in an air cycle machine cooling system does air undergo a pressure and temp drop?
Expansion turbine
In a freon vapor-cycle cooling system, where is cooling air obtained for the condensor?
Ambient air
What is ventilating air used for an combustion heater?
Carries heat to the places where it is needed
Turbine engine air used for air conditioning and pressurization is generally called
bleed air
In the combustion heater, combustion air system, what prevents too much air from entering the heaters as air pressure increases?
Either a combustion air relief valve or differential pressure regulator
How is the cabin pressure of an aircraft maintained in flight?
By controlling the rate of air flowing out the cabin
What control the operation of the cabin pressure regulator?
Cabin altitude
The basic air cycle cooling system consists of
a source of compressed air, heat exchangers and a turbine
The purpose of the dump valve in a pressurized aircraft is to relieve
all positive pressure from the cabin
What component might possibly be damaged if liquid refrigerant is introduced into the low side of a vapour cycle cooling system when the pressure is too high or the outside air temp is too low?
Compressor
How can it be determined that a vapor-cycle cooling system is charged with the proper amount of freon?
Air bubbles in the sight glass disappear
When charging a vapor cycle cooling system after evacuation, the low-pressure gauge fails to come out of a vacuum. What is indicated?
Blockage in the system
What component in a vapour cycle cooling system would most likely be at fault if a system would not take a freon charge?
Expansion valve
Frost or ice buildup on a vapour cycle cooling system evaporator would most likely be caused by
inadequate airflow through the evaporator
What test is used to determine the serviceability of an oxygen cylinder?
Pressure test with water
How often should standard weight high-pressure oxygen cylinders be hydrostatically tested?
Every 5 years
To be eligible for recharging, a DOT 3HT oxygen cylinder must have been hydrostatically tested every three years and be retired from service after
24 years or 4380 filing cycles
Which type of oxygen system uses the rebreather bag-type mask?
Continuous flow
The component that determines the pressure level in the cabin is the cabin air pressure
outflow valve
Hot compressor bleed air operates the conditioned air system on some turbine aircraft, cold air supplied by the
air cycle air conditioning
For use in pressurized aircraft, which is generally the least complicated and requires the least maintenance?
Chemical oxygen generator systems
What is the main cause of contamination of gaseous oxygen systems?
Mositure
Where does the last stage of cooling in an air-cycle air conditioning system occur?
Expansion turbine
The point at which Freon flowing through a vapour-cycle cooling system gives up heat and changes from a gas to a liquid is the
condenser
The point at which Freon flowing through a vapour-cycle cooling system gives up heat and changes from a liquid to a gas is the
evaporator
How is the cabin pressure of a pressurized aircraft usually controlled?
By an automatic outflow valve that dumps all the pressure in excess of the amount for which it is set
Which is considered a good practice concerning the inspection of heating and exhaust systems of aircraft utilizing a jacket around the engine exhaust as a heat source?
Supplement physical inspections with periodic operational carbon monoxide detection tests
On some cabin pressurization systems, pressurization on the ground is restricted by the
main landing gear operated switch
The cabin pressure control setting has a direct influence upon the
outflow valve opening
The function of the evaporator in a freon cooling system is to
lower the temp of the cabin air
What is the purpose of a mixing valve in a compressor bleed air, air conditioning system?
Control the supply of hot, cool and cold air
What component of a pressurization system prevents the cabin altitude from becoming higher than airplane altitude?
Negative pressure relief valve
If the liquid level gauge in a vapor-cycle cooling system indicates a low freon charge, the system should
be operated for a period of time to reach a stable condition and then the freon level rechecked
If the cabin rate of climb is too high, the control should be adjusted to cause
the outflow valve to close faster