Brownstones Flashcards
Engine Ops.
Cellar fire
1st Line
3.1.A
Thru front door on 1st floor, then down to cellar via int. cellar stairs
- *IF FIRE HAS CONTROL OF 1st FL. OR 1st FL. AND CELLAR = STRETCH TO 2nd FL. VIA OUTSIDE STAIRS.
- 2nd LINE WILL BE STRETCHED TO EXTINGUISH FIRE!!
**HEAVY FIRE IN CELLAR & BSMT = 2nd ALARM
Engine Ops.
Cellar fire
2nd & 3rd Lines
3.1.B & C
2nd Line: Stretched above fire. IF 1st LINE USED TO SECURE
STAIRS, 2nd LINE STRETCHED TO EXTINGUISH FIRE.
3rd Line: AS ORDERED BY IC
Engine Ops.
Fire on Upper Fl.
1st Line
3.2.A
Thru front door to fire fl.
Engine Ops.
Fire on Upper Fl.
2nd Line
3.2.B
Back up 1st line to: A- Protect advance of 1st line B- Safeguard against burst lengths C- Quicker extinguishment D- Less punishment for M's
Fl. Above NOT MENTIONED!!
Engine Ops.
Fire on Upper Fl.
3rd Line
3.2.C
As ordered by IC
Engine Ops.
Bldg. Fully Involved
1st Engine
3.3.A-C
1st arriving engine should drop 2 HAND LINES I/f/o fire bldg AND
position rig for poss use of multiversal nozzle OR to supply a TL.
Engine Ops.
Bldg. Fully Involved
1st Line
3.3.A-C
Into fire bldg thru front door
Engine Ops.
Bldg. Fully Involved
2nd Line
3.3.A-C
Into bldg as back up line
Engine Ops.
Bldg. Fully Involved
3rd Line
3.3.A-C
If fire rpt’d in exposure = stretch to that exp!!
If no fire in Exp’s = stretch THRU EXP TO REAR YARD OF FIRE BLDG.