BP 220 Flashcards
A policy of the government to promote and encourage the development of economic and socialized housing units for average and low income earners in urban and rural areas
BP 220
Refers to the most reasonable price of land and shelter based on the needs and financial capability of Program Beneficiaries and Appropriate Financing Schemes (RA 7279)
Affordable Cost
Parks and Playground Allocation : Economic Housing & Socialized Housing
For 150 and below density (# of lots per hectare)
3.5%
Parks and Playground Allocation : Economic Housing & Socialized Housing
For 151 -160 (# of lots per hectare)
4%
Parks and Playground Allocation : Economic Housing & Socialized Housing
For 161 - 175 (# of lots per hectare)
5%
Parks and Playground Allocation : Economic Housing & Socialized Housing
For 176 -200 (# of lots per hectare)
6%
Parks and Playground Allocation : Economic Housing & Socialized Housing
For 201 - 225 (# of lots per hectare)
7%
Parks and Playground Allocation : Economic Housing & Socialized Housing Above 225 (# of lots per hectare)
9% (with an addition of 1% increment for every 10 or fraction thereof above 225)
In no case shall an area allocated for parks and playground be less than how many square meters?
100 m²
According to the number of saleable lots/ dwelling units, at what density will be the neighborhood multi-purpose center be required?
Starting at 100 - 499 density
According to the number of saleable lots/ dwelling units, at what density will be there be an allocation for convenience/ retail center & elementary school?
Starting at 1500 - 1999 density
According to the number of saleable lots/ dwelling units, at what density will be the tricycle terminal be required?
Starting at 1500 - 1999 density
According to the number of saleable lots/ dwelling units, at what density will be there be an allocation for a high school?
Starting at 2000 -2499 density
What is the allocation (% of gross area) for community facilities in a 150 & below density?
1%
What is the allocation (% of gross area) for community facilities in a 151 - 225 density?
1.5%
What is the allocation (% of gross area) for community facilities in a density above 225?
2%
At what economic housing project size range do you start to have a collector road?
Above 5 - 10 hectares
At what socialized housing project size range do you start to have a collector road?
Above 10 - 15 hectares
Minimum dimensino of a Major Road
8 m
Minimum dimension of a collector road
8 m
Minimum dimension of a minor road
6.5 m
Minimum dimension of an interconnecting road
10 m
Minimum Dimension of a Motor Court ROW
6 m
Minimum dimension of Motor Court Carriageway
5 m
Minimum Dimension of an Alley ROW
2 m
Minimum Dimension of a Pathwalk ROW
3 m
Planting strip and Side walk width for 15m ROW
Planting Strip : 1.3 m
Side Walk : 1.2 m
Planting strip and Side walk width for 12m ROW
Planting Strip : 0.8 m
Side Walk : 1.2 m
Planting strip and Side walk width for 10m ROW
Planting Strip : 0.8 m
Side Walk : 1.2 m
Planting strip and Side walk width for 8m ROW
Planting Strip : 0.4 m
Side Walk : 0.6 m
Planting strip and Side walk width for 6.5m ROW
Planting Strip : Optional
Side Walk : 0.5 m
Crown roads shall have a slope of not less than __ to __ %
1.5 to 9 %
Maximum length of path walk
60 meters
Minimum Lot Area for Economic Single Detached
72 m²
Minimum Lot Area for Socialized Single Detached
64 m²
Minimum Lot Area for Economic Duplex
54 m²
Minimum Lot Area for Socialized Duplex
48 m²
Minimum Lot Area for Economic Row Houses
36 m²
Minimum Lot Area for Socialized Row Houses
28m²
Minimum Lot Frontage for Economic Housing and Single Detached Corner Lot
EH: 8m
SH: 8m
Minimum Lot Frontage for Economic Housing and Single Detached Regular Lot
EH: 8m
SH: 8m
Minimum Lot Frontage for Economic Housing and Single Detached Irregular Lot
EH: 4m
SH: 4m
Minimum Lot Frontage for Economic Housing and Single Detached Interior Lot
EH: 3m
SH: 3m
Minimum Lot Frontage for Economic Housing and Single Attached/ Duplex Lot
EH: 6m
SH: 6m
Minimum Lot Frontage for Economic Housing and Row House Lot
EH: 4m
SH: 3.5m
Maximum units per block or cluster in a row house development
20 units per block but in no case exceeding 100 meters in length
Maximum block length
400 meters
* Block length exceeding 250m shall provide a 2m alley approximately at midlength
Minimum floor area requirement for single-familty dwelling in economic housing
22m²
Minimum floor area requirement for single-familty dwelling in socialized housing
18m²
Setback/ Yard requirements (Front)
1.5m
Setback/ Yard requirements (Side Yard)
1.5m (from the building line)
Setback/ Yard requirements (Rear Yard)
2.0m
Setback/ Yard requirements (abutmenrs)
May be alowed per requirements of the National Building Code of the Philippines
Road Pavement finish for Major road
Concrete/ Asphalt
Road Pavement finish for Minor Road
Concrete/ Asphalt
Road Pavement finish for Motor Court
Macadam
Road Pavement finish for Sidewalk
Macadam
Road Pavement finish for Pathwalk/ Alley
Macadam
Minimum water supply requirement
150L per capita per day for household connection
Minimum horizontal dimension of yards
2.0m
Minimum width of a passage way connecting an inner court to a street/ yard?
1.20m
Minimum Ceiling Height
2.0m
Minimum Ceiling Height of a Mezzanine Floor
1.80m
Percentage allowed for a mezzanine floor compared to the floor area below it?
50%
Minimum clear width of a main door
0.80m
Minimum clear width of a service/ bedroom door
0.70m
Minimum clear width of a bathroom door
0.60m
Minimum area of window opening in a habitable room
At least 10% of floor area
Minimum area of window opening in bathrooms
5% of its floor area
Minimum clear width of stairways
0.60m
Maximum riser height
0.25m
Minimum tread
0.20m
Stairways not needing handrails
Stairways with 4 risers or less
Handrails height above upper surface of the tread
0.80 - 1.20m
Distance between 2 building not exceeding 2 storeys (outer wall to outerwall)
4.0m
Distance between 2 buildings with more than 4 storeys (outer wall to outerwall)
10m
* exception: when the two sides of the buildings facing each other are blank walls ; minimum distance may be reduce 2m. Distance between roof eaves shall not be less than 1m