Body Load Bulk Transport Flashcards
How Many Pods Does The Body Load Transport Have? How Big Are They
Two ASME-coded 200-ft3 pneumatic
storage tanks
What Kind of Pneumatic Power Plant Does This Unit Have
one power-takeoff-driven (PTO-driven)
air-blower assembly rated at 270 scf/min
at 29 psig
What Is The Max Working Pressure for The Two ASME-coded 200-ft3 pneumatic
storage tanks
36 psig maximum allowable working pressure (MAWP).
What Is The Maximum Pressure of TheTruck Mounted Blower
29 psig.
What Does The Gross Aeration System Do
The gross aeration system conditions materials with air, resulting in a fluid mixture or a solution of air and dry materials
What Happens When The Discharge Valves Are Opened
When the discharge valves of the
tank are opened, the pressure in the tank
forces the aerated materials to flow steadily
through the discharge line until the tank
is emptied.
How Are The Body Load Pods Aerated
Air is also fed into the top of each tank
through a 1.5-in. coupling. A vertical check valve in the top air line automatically provides a calibrated
restriction, forcing air through the aeration
pads in the bottom air line
What Are The PTO-Driven Drum Blower Specs
265 scf/min at 29 psig at 1,600 rev/min
Vehicle Empty Weight
25,780 lb (11 694 kg)
Vehicle at maximum legal weight
52,000 lb (23 587 kg)