Bleed air Flashcards
Air for the pneumatic system is normally bled from the ___ of the compressor
intermediate pressure stage
what happens in flight if pneumatic bleed air pressure is insufficient even with the HP stage valve open?>
Engines spool up automatically
what valve action automatically occurs when the apu supplies air to the pneumatic system
crossbleed valve opens and the engine bleed valves close
Pneumatic system operations is controlled and monitored by
two bleed monitoring computers (BMCs)
If BMC 1 fails, what leak detection is lost?
Engines and APU
If BMC 2 fails, what leak detection is lost
Engine 2
when will the APU bleed FAULT light illuminate
APU bleed leak detected
When will the ENG bleed fault light illuminate
Engine bleed valve not closed with the APU bleed valve open