What the 2 main types of cutting needles for needle-core biopsies?
- Tru-Cut needles - Hand powered and automated version
- Franklin-silverman needle - split needle design
To waht depth should cutting needled be placed into the tissue?
How should the sample be removed?
- At least 1.5cm into tissue of interest
- Sample removed with a 25g needle
What are the three main aspiration needle-core biopsy needles?
- Menghini
- Klatskin
- Jamshidi
Menghini has an external bevel whereas Klatskin and Jamshidi have an internal bevel allowing a larger sample with no increased risk
What is a vacuum-assisted needle-core biopsy device?
Similar to Tru-Cut but with the addition of a vacuum
How often to needle-core biopsies get a diagnosis?
How often does thi diagnosis agree with surgically obtained biopsies?
- TruCut is diagnostic in 40-97%
- Agrees with surgical biopsy in 54-94%
What range of sizes are punch biopsies available?
1-8mm
What is the recommended location when obtaining an incisinal biopsy?
At the junction of mass and normal adjacent tissue
- Must consider spread of disease to uninvolved tissue
- Avoid the periphery in bone lesions as this will most likely sample reactive periosteum
Name the following instruments
A - Laparoscopic cup biopsy forceps
B - Laparoscopic punch biopsy forceps
Cup forceps will tear whereas punch forceps will cut
Name the following instrument and its component parts
This is a self-ligating loop (SurgiTie)
- A - preformed loop
- B - Knot
- C - Nylon carrier
- D - Scored black band
- E - Proximal end
- F - Optional delivery system for endoscopic surgery
How do pre-treatment biopsies compare with post-excision histology in soft tissue sarcomas?
- 59% are in agreement
- 29% underestimate the grade
- 12% overestimate the grade
- Agreement increased to 87% when classified as low vs high
What are the three options for obtaining lymph node biopsies
- Excisional
- Guillotine (if full excision risks potential vascular damage)
- Laparoscopically with cup forceps
How to sentinel LN mapping alter treatment in dogs with MCT
Altered the treatment plan of 42% of dogs
What is the main concern regarding thyroid biopsies?
- Highly vascular - ultrasound guidance necessary, if freely movable consider excisional biopsy
Can you use automated TruCut biopsy deviced in cats?
with CAUTION!!
One study showed mortality 20% due to intense vagotonia - this was also seen at a similar rate with semiautomated devices however there were no deaths in this group
How to hepatic needle core biopsies compare with wedge/guillotime biospies?
- Only 48% agreement between needle-core and wedge
- 83.3% needle-cor biopsies are diagnostic quality compared to 100% guillotine