B777 Flashcards
(150 cards)
How many emergency exits can be found in the flight deck?
2 sliding windows
Where are the escape ropes located?
Stowed in a designated stowage compartment above each sliding window
What code is used to request entry to the flight deck in a normal situation?
1 + ENT
What is the pre-flight check of the lavatory smoke detector?
Green power indicator light is ON Smoke detector is not tampered with or obstructed
What is the pre-flight check of the lavatory waste bin automatic fire extinguisher?
Temperature indicator discs on the placard are grey/white
Where in the OFAR is the Emergency Exit Hatch located?
Is located below bunk 6
What are crew actions if the keypad on the entrance door of the OFAR is inoperative?
By using the Keypad Lock Release function in the upper RHS corner. Lift the cover flap and pull the keypad lock release lever downwards
What will you hear inside the OFAR during a decompression?
2x Lo-Hi chime + decompression horn sounds countinously
What does the green oxygen indicator light illuminating in the common area indicate?
Decompression
What are the visual indications inside the OFAR during a decompression?
The green oxygen indicator light illuminates (located in the common area)
OFAR lighting switches to full brightness (100% bright)
Oxygen masks in the OFAR are deployed
What are the aural indications inside the OFAR if smoke is detected?
5x Hi-Lo chimes sound+ smoke detector alarm horn
What are the visual indications inside the OFAR if smoke is detected?
The red smoke detector alarm indicator light illuminates
All compartment lights illuminate (full brightness)
The air supply valves are closed and the compartment exhaust valves are opened
What is the visual indication on the Entrance Main Control Panel of the OFAR if smoke is detected?
The AIRFLOW OFF light at the entrance main control panel illuminates
What is the aural indication in the cabin if smoke is detected in the OFAR?
Continuous chime sounds in doors LR4, LR5 and aft galley
What is the visual indication in the cabin if smoke is detected in the OFAR?
Amber light above OFAR entrance enclosure flashes
MCL amber lights flash in the cabin
What is the visual indication at L1 station if smoke is detected in OFAR?
SMOKE DETECTED pop-up message appears on CSCP/CACP screens
How is the smoke detection horn silenced from inside the OFAR?
Press HORN SHUT OFF switch
How are the OFAR smoke detection alarm horn and chimes silenced in the cabin?
A crew member in the cabin shall press the amber reset switch above the entrance door to silence the alarm horn and chimes
How is OFAR smoke detection system reset?
When the smoke clears, the red alarm indicator light on each smoke detector switches off to indicate normal smoke detector function has been restored
What will you see in the Master Call Light (MCL) when a Passenger call is made from the Lavatory?
Amber Steady
how is an Emergency Call to the flight deck made using the cabin interphone?
3*
What is the first step in detaching the slide/raft?
Pull the manual inflation handle free of the fabric flap over the girt bar
What will you hear in the cabin if a lavatory smoke detector is activated?
Continuous chime
What will you see on the Master Call Light (MCL) if smoke is detected in a lavatory?
Amber flashing