B312.1 Use of Radiological Pagers (02-01-2013) Flashcards

1
Q

[B312.1 Use of Radiological Pagers]

Rad pagers should be used as what 2 devices?

A
  1. Dosimeter (Accumulated dose)
  2. Dose rate warning device
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

[B312.1 Use of Radiological Pagers]

What is the only way to determine the presence of radiation?

A

Radiological monitor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

[B312.1 Use of Radiological Pagers]

Rad pagers will continuously monitor for what type of radiation?

A

Gamma radiation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

[B312.1 Use of Radiological Pagers]

The rad pager will give an audible alarm at the presence on gamma radiation at or above:

A

2 millirem

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

[B312.1 Use of Radiological Pagers]

Where will the rad pagers be located?

A

In a pouch mounted in the cab

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

[B312.1 Use of Radiological Pagers]

Who will perform a maintenance and performance test of the rad pagers on a regular basis?

A

SpecOps Support

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

[B312.1 Use of Radiological Pagers]

All units will utilize the rad pager when responding to any reports of:

A

An explosion, or emergency incident where the known or suspected release of radiation is possible

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

[B312.1 Use of Radiological Pagers]

When should the initial benchmark be noted?

A

As soon as they exit the truck

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

[B312.1 Use of Radiological Pagers]

The first arriving company should do what 4 things?

A
  1. Size-up
  2. Identify
  3. Isolate
  4. Notify dispatch and incoming units of conditions
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

[B312.1 Use of Radiological Pagers]

At what point should the exclusion zone be established?

A

2 millirem/hr total dose rate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

[B312.1 Use of Radiological Pagers]

What is the total dose allowed during normal emergency response operations?

A

5 rem total dose

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

[B312.1 Use of Radiological Pagers]

What is the turn back dose?

A

200 rem/hr or 25 rem total dose

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

[B312.1 Use of Radiological Pagers]

Can the rad pager be silenced if it reads 200 rem/hr or 25 REM total dose?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

[B312.1 Use of Radiological Pagers]

Can the rad pager be silenced if it reads 2 millirem/hr total dose rate?

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

[B312.1 Use of Radiological Pagers]

Can the rad pager be silenced if it reads 5 rem total dose?

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

[B312.1 Use of Radiological Pagers]

What kind of alarms will activate when the rad pager reads alarming levels of radiation?

A

Audible and visible

17
Q

[B312.1 Use of Radiological Pagers]

What should companies do when the pager activates?

A

Make note of the activation notify dispatch and incoming companies

18
Q

[B312.1 Use of Radiological Pagers]

What should companies do if the alarm activates and are unable to reset it?

A

Make note and immediately leave, notify dispatch and incoming companies

19
Q

[B312.1 Use of Radiological Pagers]

Who shall be notified immediately in the event of any known or suspected release of radiological material, and who shall notify them?

A

Texas Bureau of Radiation Control

-Command should have dispatch assist in notifying them

20
Q

[B312.1 Use of Radiological Pagers]

What is the radiation axiom that should guide rescue efforts?

A
  • Time
  • Distance
  • Shielding