B312.1 Use of Radiological Pagers (02-01-2013) Flashcards
[B312.1 Use of Radiological Pagers]
Rad pagers should be used as what 2 devices?
- Dosimeter (Accumulated dose)
- Dose rate warning device
[B312.1 Use of Radiological Pagers]
What is the only way to determine the presence of radiation?
Radiological monitor
[B312.1 Use of Radiological Pagers]
Rad pagers will continuously monitor for what type of radiation?
Gamma radiation
[B312.1 Use of Radiological Pagers]
The rad pager will give an audible alarm at the presence on gamma radiation at or above:
2 millirem
[B312.1 Use of Radiological Pagers]
Where will the rad pagers be located?
In a pouch mounted in the cab
[B312.1 Use of Radiological Pagers]
Who will perform a maintenance and performance test of the rad pagers on a regular basis?
SpecOps Support
[B312.1 Use of Radiological Pagers]
All units will utilize the rad pager when responding to any reports of:
An explosion, or emergency incident where the known or suspected release of radiation is possible
[B312.1 Use of Radiological Pagers]
When should the initial benchmark be noted?
As soon as they exit the truck
[B312.1 Use of Radiological Pagers]
The first arriving company should do what 4 things?
- Size-up
- Identify
- Isolate
- Notify dispatch and incoming units of conditions
[B312.1 Use of Radiological Pagers]
At what point should the exclusion zone be established?
2 millirem/hr total dose rate
[B312.1 Use of Radiological Pagers]
What is the total dose allowed during normal emergency response operations?
5 rem total dose
[B312.1 Use of Radiological Pagers]
What is the turn back dose?
200 rem/hr or 25 rem total dose
[B312.1 Use of Radiological Pagers]
Can the rad pager be silenced if it reads 200 rem/hr or 25 REM total dose?
No
[B312.1 Use of Radiological Pagers]
Can the rad pager be silenced if it reads 2 millirem/hr total dose rate?
Yes
[B312.1 Use of Radiological Pagers]
Can the rad pager be silenced if it reads 5 rem total dose?
Yes