Auxiliary Power Unit Flashcards
After three consecutive APU start attempts, the flight crew must wait … min before a new start attempt.
60
Maximum APU Rotor N speed
107 %
Maximum EGT for APU start
1 250 °C
Maximum EGT for APU running
650 °C
During refuel/defuel procedures, APU starts or shutdown are permitted with the following restrictions:
‐ If the APU failed to start or following an automatic APU shutdown, do not start the APU
‐ If a fuel spill occurs, perform a normal APU shutdown.
When JET B or JP4 is used, APU operation is limited to …
25 000 ft
APU ground operation maximum altitude
14 600 ft
APU flight operation maximum altitude for bleed air and electric power:
22 500 ft
APU flight operation maximum altitude electric power only:
41 450 ft
APU Battery Restart Limit
25 000 ft
APU maximum altitude to assist engine start
20 000’
APU Max altitude for air conditioning and pressurization (single pack operation)
22 500’
APU Max altitude for air conditioning and pressurization (dual pack operation)
17 500’
APU bleed air for wing anti-ice is …
Not permitted