Auxiliary Power Unit Flashcards
The type of APU installed is a _____.
Honeywell 36-150BD
The primary function of the APU is to _____.
start the engines
The APU fuel burn is _____ lb/hr.
150
Is there an external APU shutoff?
Yes—on the External Power Control Panel,
below the right engine.
The APU gets fuel from _____
the right collector tank
Fuel is fed to the APU fuel pump via the _____.
right DC fuel pump until RT engine is running,
then the main ejector pump supplies the
pressurized fuel
When the airplane is being de-iced prior to departure, consider that _____.
de-icing with the APU running is prohibited
Prior to starting the APU, ensure a minimum battery voltage of _____ volts.
> 20
The APU provides the following 4 functions: _____.
-Bleed air for air conditioning
-Pressurization
-Engine start
-DC power
What is the only fire bottle dedicated to the APU?
The number 2 bottle
Is the APU fire protection system automated while on the ground and while the extinguisher discharge
Yes, and the extinguisher 5 seconds after shutdown.
Can the APU be operated with the APU generator inoperative?
Yes per the MEL
When starting the APU, the right battery _____ and the left battery _____
PBA shows OFF and is powering only the APU starter
Is powering the rest of the aircraft, including the start logic for the APU
_____ total start attempt(s) is/are allowed for the APU on the ground, limited to _____.
three
1 min cooling between attempts, then
20 min cooling, two start attempts with 1 min
cooling between attempts, then 40 min cooling
How many times are allowed to start the APU in the air?
Once