Where does the VENTILATION SUPPORT GROUP report to and what tools does it bring?

A
INCIDENT COMMAND POST
Tools: 
-27' Tempest PPF and exhaust hoses
-Eye and ear protection
-Dave Clark headset
-HT's
-CO monitors
-ELEVATOR keys
-Halligan, heavy axe (ELEVATOR OPS)
-door chicks
-hand LIGHTS
-SCBA and full PPE
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

6.3

True or False: THE VENT SUPPORT GROUP SUPERVISOR SHALL INFORM THE IC OF THE RECOMMENDED PLACEMENT OF THE PFFs.

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

6.3

Proper fan placement is based on what 4 factors?

A

1) #OF PPF s available
2) location of fire floor
3) #OF FLOORS in the building
4) stage of firefighting operations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

6.4

PPF’s should _____be left unattended. A _______ member must continually monitor each operating fan.

A

Never

Radio Equipped

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

6.3

True or False ONLY THE IC CAN AUTHORIZE STAIRWELL PRESSURIZATION.

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
7.1
Pressurizing the attack stairwell is most effective when done\_\_\_\_\_
A) after the fire has been knocked down
B) Prior to fire attack
C) simultaneously with fire attack
A

B) SIMULTANEOUSLY WITH THE FIRE ATTACK

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

7.2
The optimum placement of the PPF is ____from the attack stairwell door on the ground floor and directly facing the door to the stairwell at an angle of____.

A
  • 4-6FT

- 80°

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

There are ___ tilt positions on the foot pedal. The fan should be positioned to blow into the stairwell it should not be placed _____.

A
  • 5 tilt positions

- INTO THE STAIRWELL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
7.3
The pressure delivered into the attack stair by the PPF will be great enough to allow for how many stairwell doors to be open?
A) 1
B) 2
C)3
D)4
A

C) 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

7.3

Who will check the attack stair doors BELOW the fire floor to verify that they are maintained closed.

A

VENT GROUP MEMBERS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Upon request of the Vent Group Supv who will the IC order to verify attack stair doors ABOVE the fire floor are maintained closed?

A

3rd and 4th Due Ladder Co’s

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

1 PPF can provide the proper pressure in the STAIRWAY up to ___ stories depending on CONDITIONS and 2 fans will pressurize a _____story BUILDING when properly positioned.

A
  • 10 stories

- 40 stories

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Where would the second fan be positioned for a fire above the 10th FL or if additional pressure was required?

A

3 floors below the fire floor

-same distance and angle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

8.1

During sequential ventilation where shall the PPF be placed

A

THE EXTERIOR OF THE BUILDING

- -EITHER ON THE GROUND FLOOR OR IN THE CELLAR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

8.1
iF CO levels are in the ____ PPM range, gasoline powered PPFs will not significantly reduce due to levels CO emissions produced by the fans.

A

0-60 PPM RANGE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When Positive pressure mechanical ventilation (used for large areas: subways, schools, hospitals, theatres, etc) is implemented, where is the ideal location for the exhaust opening?

A

As close to the seat of the fire as possible, as high as possible.
(The opening should be double the size of the opening where the PPF is placed.)

17
Q

10.1
Negative pressurization utilizes the electric box fan operated in exhaust mode. The fan should be positioned _____ FEET back from the exhaust opening and tilted at a_______ angle.

A
  • 6-8 feet

- 30° angle

18
Q
11.7
How often shall the fans be inspected?
A) DAILY AND AT MUD
B) WEEKLY AT MUD
C) MONTHLY
D) WEEKLY AND AFTER EACH USE
A

A) DAILY (beginning of 9x6 TOUR) AND WEEKLY AT MUD

*At MUD started and run at FULL RPM FOR 5 MIN. DO A VISUAL INSPECTION OF THE FAN BELT AND TIGHTNESS CHECK.

19
Q

TRUE OR FALSE

IF THE FAN MUST BE MOVED DURING OPERATION YOU NEED 2 MEMBERS.

A

FALSE. NEVER MOVE FANS DURING OPERATION

NEVER REFUEL INSIDE A STRUCTURE