AUC 180 230 231 253 Flashcards

1
Q
Fire in a 75' Hi Rise Office Bldg with fire issuing from a room reading "Caution-Transformer-High-Voltage" 
A. 10-84, 10-75, 10-25 Code 1
B. 10-84, 10-76, 10-25 Code 2
C. 10-84, 10-76, 10-25 Code 4
D. 10-84, 10-77, 10-25 Code 4
A

C Code 4: Fire or smoke condition from a transformer at any location, i.e., pole, vault, room, etc.
AUC 180

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Choose correct for Transformer Vault
A. Greatest hazard is amt of electricity, but asbestos and PCB’s may also be present
B. All transformers in vaults contain dielectric oil w/PCB’s in the 10-49 PPM range. Treat as Non-PCB Transformer and operate as if no PCB’s are present
C. Transformers convert primary voltage (27,000 Volts) to secondary voltage (120 V) and members should only be concerned w/higher voltage
D. Transformer vaults are located underground and easily noticed by members

A

A
B FDNY considers a transformer with any amount of PCBs as a PCB Transformer. Operate accordingly.
C Either of these voltages can cause fatal injury if not handled properly.
AUC 180

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Operating at Transformer Vault choose correct (3)
A. Due to amt of flammable liquid, stretch a precautionary HL and be prepared to initiate foam ops
B. Teams of 2 shall examine exp for CO readings in meter room, surrounding rooms, and 1st fl
C. Make entry into vault prior to Con Ed if a known life hazard exists
D. Be prepared to re-examine exp on a periodic basis as conditions change rapidly

A

A, B D
C Members are not to enter these vaults until Con Edison has made their examination.
AUC 180

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Smoking manhole and utility co has given 25 minute ETA, choose correct
A. Leave 1 Eng on scene awaiting arrival of Utility Co
B. Protect manhole by traffic cones and tape and place all unit I/S
C. Leave 1 unit on scene to respond to any alarms received; one FF may be left on scene
D. Leave 1 FF at scene and have unit return to qtrs. Off shall provide relief for members

A

A ETA Under 30 minutes, may leave a unit on scene (preferably an Engine)
AUC 180

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Incorrect Con Ed Shift Manager
A. If an incident becomes more severe than originally stated, BC can telephone Con Ed Shift Manager directly, via cell phone
B. If Con Ed ETA is not satisfactory, BC can call Electric Control Center Shift Manager to clarify
C. Response to Con Ed Substation that is not staffed, telephone area’s Electric Control Shift Manager
D. Con Ed has cell phone numbers for each Battalion if they need to speak to on-site BC

A

C Chief should contact Con Ed Substation Shift Manager via phone
Note: Con Edison Substations do not fall under the jurisdiction of the Electric Control Center
AUC 180

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Fire Ice Incorrect
A. Fire Ice coats burning electrical cables, preventing cable fires from extending beyond affected manholes
B. When BC employs Fire Ice- simultaneously request Con Ed Supervisor and Fire Ice Unit
C. Only a Chief can order application of Fire Ice after consulting with on scene Con Ed Supervisor
D. Fire Ice is not effective on Class B fires. Therefore, it is not intended for any type of transformer fire

A

C When necessary, BC may order application of FireIce prior to the arrival of a Con Ed Supervisor. Objective is to enable BC’s operating at a 10-25 code 1 or code
2 manhole incidents the opportunity to suppress fires prior to the utility company arrival at the scene.
AUC 180

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Large padlocks w/hardened shackles given to BC to secure premise when no owner present incorrect
A. Used only on commercial occupancy; these locks shall never be used when fire is encountered
B. FE accomplished w/minimal damage and no other damage to entire perimeter of premise
C. Original padlock hasp and staples in place, and can be easily secured w/padlock
D. Nothing abnormal or unusual about premise or its contents

A

A Minor fires only it is ok to use

AUC 231

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Incorrect for BC securing premise w/Gravoply lock
A. Battalions carry locks and keys in Battalion car. Keys and lock shall be properly tagged
B. BC shall issue a padlock and key to a company at scene and direct the company to secure the premises
C. 2nd key shall be kept in firehouse HW area that the Battalion is quartered with in case of loss of key carried in car
D. If Unit is at an extended ops when lock is requested to be removed, Dispatcher shall notify BC. BC shall take actions to see lock removed

A

C Second key shall be kept in Battalion office in event of loss of key carried in car
AUC 231

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Correct info for Red Cross at fires
A. Red Cross provides response of their personnel to all 2nd/greater alarms in occupied, unoccupied, or vacant bldgs
B. Red Cross Referral Slip shall only be given to persons needing relocation or assistance as a result of fire as it serves as verification of fire, damage, or residence
C. Persons requiring assistance will make the necessary telephone call to Red Cross per instruction on Referral Slip. Under no circumstances shall FD members make these calls on their behalf
D. Referral Slips need not be given if Red Cross personnel on scene

A

D
A Response of their personnel to all 2nd or greater alarms in occupied buildings
B Referral Slips shall be given to any person needing relocation/assistance as a result of fire. The slip may be given to anyone who wants one. It will not be recognized by any agency as verification of fire, damage or residence. It is merely a referral.
C An exception to procedure will be made if victim has no access to a telephone or when a severe language problem exists
AUC 253

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

After using Battalion lock to secure a premises, who is responsible to notify Dispatcher for entry
A. Co Off from the scene, he should place key on rig
B. Co Off, on return to qtrs, place key on rig
C. BC from scene and place key in Battalion rig
D. BC on return to qtrs, and place key in office

A

B

AUC 231

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

RAC incorrect
A. At 2nd/greater alarm fires, or as determined by the IC, all FFs exposed to products of combustion shall have their oxyhemoglobin (SpO2), and carboxyhemoglobin (SpCO) levels measured with a RAD – 57 Pulse CO-Oximeter.
B: Members entering rehab should normally rest for approx 20 min before being reassigned. Depending on conditions, the IC, in consultation with the Medical Branch Director, may modify the time frame for rehabilitation.
C: Rehabilitation Group shall be est by the IC at 3rd alarm/greater fires. At long duration and/or physically demanding incidents or in extreme temperatures, the IC should est a Rehabilitation Group.
D: When the Rehabilitation Group is established, the Medical Branch Director will designate an EMS Officer as the Rehabilitation Group Supervisor

A

C. Rehab Group shall be established by the IC at 2nd alarm or greater fires.
AUC 230

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q
Rehabilitation Group: Which chief is in charge of sending companies to the Rehabilitation Group?
A: IC
B: Operations Section Chief
C: Safety Chief
D: Resource Unit Leader
E: Sector Chief
A

D AUC 230 sec 3.2
Know all the responsibilities of the RUL check out sec 3.3 and 3.5. Remember, the Rehabilitation Group shall be est by the IC at 2nd alarm or greater fires/long duration and/or physically demanding incidents or in extreme temperatures

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Incorrect for Transformers
A: Con Edison does not test pole mounted transformers for PCB content.
B: Almost all of Con Edison’s overhead transformers are not, or were not, designed to be PCB liquid filled. They are mineral oil transformers.
C: Due to past storage and/or servicing practices some of these transformers have become PCB contaminated, i.e., 50-499 PPM PCB. None will be PCB Transformers (500 PPM or greater).
D: All new transformers being installed by Con Edison as replacements for existing ones and/or new installations are non-PCB transformers.

A

C Small percentage of these transformers have attained levels of 500 PPM PCB or greater which classifies them as PCB transformers.
AUC 180 Ref 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Red Cross correct
1) Red Cross referral slips are distributed to all battalions
2) The Red Cross referral slip may be given to anyone who wants one even if the person had no fire damage to their occupancy
3) Box #, date, time of Box, and Division that responded to incident will be inserted on slip when it is given to victims
4) Battalions will no longer use radio communications for relocations of victims of fire
5) The person requiring assistance will make necessary telephone call to the Red Cross per instructions on Referral Slip. An exception to procedure will be made if victim has no access to a telephone or when a severe language problem exists
6) Referral slips need not be given if Red Cross personnel are on the scene
A: 1,2,3,4,5,6
B: 1,2,3,4,5
C: 1,3,4,5
D: 1,2,4,5,6
E: 1,3,4,5,6

A

D
3) Box number, date, time of Box, and the Battalion responsible for the fire report will be inserted on slip by responsible Battalion at scene when it is given to victims AUC 253

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Some conditions that might require a call to a Con Edison Shift Manager can be found in all of the following except?
A: Fire condition becomes more severe than originally reported
B: Dangerous CO conditions in surrounding properties
C: Additional manholes or equipment showing activity
D: Transformer fire affecting one occupancy
E: Sensitive or high-profile occupancy

A

D Transformer fire affecting several occupancies
Remember, If a Con Ed Substation is involved, Chief officers can contact the Con Edison SUBSTATION Shift Manager. This is different than the Electric Control Center
AUC 180 add 1 sec 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

RAC incorrect
A: One RAC Unit will respond to signal 10-75 and greater alarms, 10-60, 10-76, 10-77, and when special called by the IC. At an expanding or extended operation, additional RAC Units may be special called.
B: Members entering rehab should normally rest for approx 20 minutes before being reassigned. Depending on conditions, the IC, in consultation w/Rehab Group Manager, Medical Branch Director or designee, may modify the time frame for rehabilitation.
C: At 2nd or greater alarms or when special called for by the IC, the RUL shall assign units being relieved or released to the Rehabilitation Group, as appropriate. Units shall be sent in manageable groups, usually three units at a time, so as to not overcrowd the Rehab Group
D: The RUL shall use the Rehab Tracking Sheet and/or the Incident Command Application to document which units and members have reported to, and have been evaluated by the Rehab Group. Once members complete the rehab process, they may become available for another assignment

A

C Four units at a time

AUC 230 sec 7.2, 7.4, 7.5 and add 1 sec 3.1

17
Q

Incorrect about RAC
A. RAC Unit may be special called by an IC
B. Rehab can take place with or without establishment of a formal functional area
C. During routine incidents, companies can conduct rehab on their own
D. Company rehab should not occur during an SCBA cylinder change, the transition from active fire attack to overhaul, or other similar situations

A

D Company rehabilitation can occur during an SCBA

cylinder change, the transition from active fire attack to overhaul, or other similar situations

18
Q

RAC incorrect
A. RAC Units are automatically dispatched on a 10-75, 76, 77, or 60
B. RAC ops will be conducted at an area known as the Forward RAC Area
C. Forward RAC Area will be the location of the Rehabilitation Group
D. Aim is to have the Forward RAC Area within 50’ of the fire bldg and within eyesight of the ICP whenever possible

A

D Within 50’ of Command Post and within eyesight of Fire Bldg whenever possible

19
Q

Correct for RAC (3)
A. 2nd/greater alarms, 10-60, and prolonged incidents a Rehab Manager will supervise RAC Unit and assist in coordinating of add’l resource needs for the Rehab Group
B. 2nd/greater alarms or when special called, RESL shall assign units being relieved or released to Rehab Group
C. Units shall be sent to Rehab Group in manageable numbers usually 3 units at a time
D. Members entering rehab should normally rest for approx 30 minutes before being reassigned
E. At expanding incidents, the Medical Branch Director, in consult w/IC or Rehab Manager shall reevaluate location for Forward RAC Rehab Area

A

A B E
C 4 units at a time
D 20 minutes

20
Q

Incorrect for RAC Units (2)
A. If a RAC Unit is staffed with one FF and responding, an additional RAC Unit will be requested by the responding RAC FF
B. 2nd RAC Unit operating because the 1st RAC Unit had only one FF will operate until released by the IC or Rehab Manager
C. An additional RAC Unit will respond to transmission of a 4th alarm, unless an add’l RAC Unit has already been assigned
D. RAC FF’s will be responsible for collection of member’s personal hoods who operated in an IDLH to have them decontaminated. This is not optional

A

C 3rd Alarms
D RAC Firefighters will be responsible for the collection of member’s personal hoods who wish to have them decontaminated by the FDNY Decontamination Support Unit

21
Q

Which 10-25 code did BC Manhole transmit correctly?
A: 10-25-4 for a popping noise coming from a transformer
B: 10-25-2 for smoke seeping from a manhole
C: 10-25-3 for a popping noise coming from a manhole
D: 10-25-1 for a transformer fire that extended into a building

A

D
A- 10-25 without code
B- 10-25-3
C- 10-25 without code
10-25-1 Fire has extended from a manhole, conduit, or transformer into a building
10-25-2 Fire has blown one or more manhole covers, or smoke is issuing from a manhole under pressure
10-25-3 Smoke is seeping from a manhole
10-25-4 Fire or smoke condition from a transformer at any location (pole, vault, room, etc)
10-25 without code situation other than described in codes 1,2,3,4
AUC 180 sec 1.1

22
Q

Rehab Group at a 10-75 will consist of:
A. RAC Unit, BLS Crew, EMS Officer
B. RAC Unit, ALS Crew, EMS Officer
C. RAC Unit, BLS Crew, BLS Crew, EMS Officer
D. RAC Unit, BLS Crew, ALS Crew, EMS Officer

A

D

23
Q

Which of the following statements is MOST CORRECT according to department policy?
A: At 2nd or greater alarm fires and long duration and/or physically demanding incidents, a Rehabilitation group shall be established by the IC
B: RAC Unit will respond on 1075 and greater alarms, 1060, 1076, 1077 and when special called. A Rehabilitation Manager will respond on 2nd and greater alarms, 1060, and when special called.
C: At 2nd or greater alarms, or when special called for by the IC, The Rehabilitation Manager shall assign units being relieved or released to the Rehabilitation group.
D: When a Rehabilitation Group is established, all members shall have their oxyhemoglobin and carboxyhemoglobin levels measured.

A

B
AUC 230 Addendum
A – Incorrect 7.1 – 1075 or Greater
C – Incorrect - Resource Unit leader does this 7.4
D – Incorrect – All members EXPOSED to products of combustion 7.8