APU Fire Panel Flashcards
What controls the APU automatic functions?
The ECB (Electronic Control Box)
What fire detection and suppression does the APU have?
Detection: There are 2 Gas filled loops
Suppression: 1 Halon Bottle
When will a APU Fire Warning be issued?
- Both Loops detect a fire.
- One loop detects a fire and the other loop is inoperative.
- Both loops break within 5 seconds of each other.
If the APU PB is pushed, what happens?
(Walk the panel)
CRC is silenced.
The APU shuts down.
Arms the Squib.
APU fuel pump shuts off (FWD+AFT).
LP Fuel valve closes.
The APU Generator Deactivates.
The APU bleed valve and crossbreed close.
If the APU fire test button is pushed, what happens?
2 Master warning lights illuminates (Red)
APU fire PB light illuminates (Red)
APU Fire Warning message (Red)
Agent Squib light illuminates (White)
Discharge PB illuminates (Amber)
CDC
5 Lights a Message and a CRC. (3 Red lights, 1 Red APU Fire Warning message, 1 Amber light, 1 White light)