APU Fire Panel Flashcards

1
Q

What controls the APU automatic functions?

A

The ECB (Electronic Control Box)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What fire detection and suppression does the APU have?

A

Detection: There are 2 Gas filled loops

Suppression: 1 Halon Bottle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When will a APU Fire Warning be issued?

A
  • Both Loops detect a fire.
  • One loop detects a fire and the other loop is inoperative.
  • Both loops break within 5 seconds of each other.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

If the APU PB is pushed, what happens?

A

(Walk the panel)
CRC is silenced.
The APU shuts down.
Arms the Squib.
APU fuel pump shuts off (FWD+AFT).
LP Fuel valve closes.
The APU Generator Deactivates.
The APU bleed valve and crossbreed close.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

If the APU fire test button is pushed, what happens?

A

2 Master warning lights illuminates (Red)
APU fire PB light illuminates (Red)
APU Fire Warning message (Red)
Agent Squib light illuminates (White)
Discharge PB illuminates (Amber)
CDC

5 Lights a Message and a CRC. (3 Red lights, 1 Red APU Fire Warning message, 1 Amber light, 1 White light)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly