APU Flashcards

1
Q

What are the different modes and when do they occur?

A

APU Attended Mode - When any engine is running or starting or when airborne

APU Unattended Mode - Operates all other times the aircraft is on the ground with no engines running or starting

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When will the APU shutdown in Attended Mode?

A

APU fire/inlet over temperature
overspeed/loss of overspeed protection
APU controller failure
Speed Droop

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When will the API shutdown in Unattended Mode

A

Generator oil filter approaching bypass
intake door failure
no combustion on start
no acceleration on start

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When does APU Limit displace on EICAS

A

High EGT
High Oil Temperature
Low Oil Pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When would the APU automatically start?

A

Loss of both Main and Backup generators

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Explain APU Shutdown

A

Rotate APU selector to OFF begins shutdown cycle of 105 seconds by closing the APU BLEED AIR VALVE. APU continues running for a cooldown period. EICAS memo APU COOLDOWN during this time. After cooldown, FUEL VALVE closes and APU shuts down.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What causes the APU bleed valve to open automatically?

A

It is armed to open whenever the APU is running and the altitude is less than 22,000 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What other fuel pump source is available to the APU?

A

There is a DC fuel pump in the left main for APU start when no AC is available.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How many fire warning loops does the APU have?

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Does the APU have overheat protection?

A

No, only fire detection…no overheat detection.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How many loops are required to sense a fire for auto shutdown of the APU?

A

On the ground - only one loop

In the Air - both loops must be functioning and sensing fire.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What bus does the APU automatically connect to when started on the ground?

A

Left main AC bus.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What will cause an automatic shutdown of the APU on the ground?

A
  1. Fire warning
  2. high oil temp
  3. low oil pressure
  4. High EGT
    * *On the ground, APU fire warning also discharges the bottle.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What will cause an automatic shutdown of the APU in flight?

A

APU fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If the APU auto shuts down in flight because of a fire warning, will the bottle discharge automatically?

A

No, the crew will have to discharge it.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What happens when you pull the APU fire switch?

A
  1. Shuts off fuel, air, electric
  2. Closes the APU door
  3. Arms the bottle for discharge
17
Q

When is the APU fire switch lock automatically released?

A

When a fire is detected.

18
Q

What does the APU FAULT light mean?

A
  1. High EGT
  2. High oil temp
  3. Low oil pressure
19
Q

When does the APU start automatically?

A

In flight if both AC transfer busses lose power.

20
Q

What is the altitude limit for APU starting?

A

43,100 ft.