APU Flashcards

1
Q

If an APU Fire is detected on the ground:

A

The APU automatically shuts down and the halon extinguisher is automatically discharged.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The APU may be started and operated in flight. Which of the following is also true?

A

The APU may be operated up to the maximum certified pressure altitude of 39,000 feet.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

You have just selected the APU MASTER SW pb to ON. You now select the APU START pb to ON. Which statement is correct?

A

The ECB will not engage the electric starter until the power-up self test is completed satisfactorily and the air intake flap is fully open.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How do you start the APU?

A

Press the APU MASTER SW pushbutton, followed 3 seconds later, by the APU START pushbutton.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Normally, how do you shut down the APU?

A

Press the APU MASTER SW pushbutton only.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The APU generator has the same power output as an engine generator.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Fuel for APU operation is normally supplied from:

A

The left fuel feed line, through the engine 1 feed line.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How do you start the APU?

A

Press the APU MASTER SW pushbutton, followed 3 seconds later, by the APU START pushbutton.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Normally, how do you shut down the APU?

A

Press the APU MASTER SW pushbutton only.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The APU Systems Display shows that the APU is providing bleed air.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The APU bleed duct is connected to the right side of the aircraft’s pneumatic system.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Which APU status is correctly displayed?

A

APU Shutdown

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Which APU status is correctly displayed?

A

APU operating, supplying bleed air and electrical power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Which APU status is correctly displayed?

A

APU operating, supplying electrical power only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly