AOI Flashcards
AOI-2
Rod Control
AOI-3
Dilution/Boration malfunction
AOI-18
Malfunction of Pzr Press control
AOI-4
NIS Malfunction
AOI-20
Malfunction of PZR level control
AOI-16
Loss of normal Feed
AOI-24
RCP Malfunction
AOI-39
Rapid load Reduction
AOI-21
Loss of 125VDC Vital Battery Boards
AOI-37
Turbine Runback Response
AOI-25
Loss of 120 V AC
AOI-44
Eagle 21 Malfunctions
AOI-26
Loss of control room annunciations
AOI-11
Loss of vacuum
AOI-2 Immediate actions
1.Rods moving If there is uncontrolled rod motion then place control rods in Manual
Check rods stopped if rods continue to move trip reactor
2.Dropped rod. If only 1 rod dropped place rod control to manual
If more than one rod dropped trip reactor
AOI-18 Immediate actions
Monitor RCS pressure stable.
Restore press to normal using Manual control
If PZR pressure drop due to failed PORV then close PORV and or block valves for failed PORV
If PZR pressure drop due to failed spread valves the close failed spray valves manually
AOI-4 Immediate actions
Place rods in Manual check rod motion stopped
If rods continue to move trip reactor
AOI-13
Loss of ERCW
AOI-15
Loss of CCS
AOI-46
Loss of ERCW
AOI-10
Loss of air
AOI-17
Turbine trip
AOI-41
Condenser Tube leak
AOI-6
RCS leak