Alignment Flashcards
This is the condition where the centrelines of two coaxial shafts don’t form a straight line
Misalignment
The four kinds of misalignment
Vertical Angular
Horizontal Angular
Vertical Offset
Horizontal Offset
What kind of shims are recommended
Pre cut stainless steel (standard thickness from 0.001” to 0.125”)
The four standard sizes of shims
Class A: 2”x2”
Class B: 3”x3”
Class C: 4”x4”
Class D: 5”x5”
How many shims should you use max
3, maximum 4
Largest on bottom, second largest on top, smallest in the middle
Should you back off the jackscrews before tightening hold down bolts?
Yes
When the dial indicator on a is depressed the gauge is what?
Positive
TIR stands for what?
Total Indicator Reading
Two types of runout
Eccentric and angular
Correction for vertical alignment formula
A/D x Feeler calculation = Front shim change
B/D x Feeler calculation = Back shim change
D= coupling diameter, A= distance to front foot, B= distance to back foot
For soft foot the rule of thumb is to use this much of the value shown on the dial indicator for shimming
80%
The most accurate way to measure for soft foot
Feeler gauges at the four corners of the foot