AIR CONDITIONING PANEL Flashcards
The pneumatic system is monitored and controlled by?
2 Bleed Monitoring Computers (BMC)
If one BMC fails, can the other take over?
a. Yes, they are interconnected. If BMC 1 fails:
b. APU and ENG 1 leak detection are not monitored
c. ECAM APU BLEED LEAK warning is lost
The PACK FLOW selector has LO, NORM, and HI positions (A319/320). What does this allow us to do?
Select pack flow rates representing LO 80%, NORM 100%, and HIGH 120% of NORM
What flow rate is automatically selected when APU bleed air is in use or during single pack operation?
Hi
When should the PACK FLOW selector not be in the normal position?
a. Less than 115 guests, select LO
b. Hot and humid conditions, select HI
c. During Smoke/Fumes removal, select HI as per the procedure
If the engine bleed air in-flight is too low what will occur?
Engine speed is automatically increased to provide adequate bleed air pressure
What would cause an amber FAULT light to illuminate in the PACK 1 and/or Pack 2 pushbutton (OOD)?
a. Overheat - Pack outlet
b. Overheat - Compressor outlet
c. Discontinuity - Switch position disagreement with pack flow control valve
d. Note: FAULT light will be illuminated when no bleed air is supplied
What does the amber FAULT light in the APU BLEED pushbutton indicate?
Bleed leak (APU bleed valve closes)
What causes the amber FAULT light on the ENG 1 BLEED and/or ENG 2 BLEED pushbutton (OOLD)?
a. Overpressure - Downstream of the bleed valve
b. Overheat
c. Leak - Low pressure
d. Discontinuity - APU bleed valve open and engine bleed valve not closed or
e. Engine Start with bleed valve not closed
What are the two functions of the engine bleed valves?
a. Pressure regulation
b. Shut off valves
At what cabin differential pressure does the RAM AIR valve open?
1 PSI ΔP or less
What logic controls the X-Bleed valve when the X-BLEED switch is in AUTO?
a. When APU bleed valve is OPEN, the X-Bleed valve is open
b. When APU bleed valve is CLOSED, the X-Bleed valve is closed
c. X-Bleed also CLOSES for wing, pylon, or APU duct leak (except during engine start)
What causes the Pack Flow Control valve to automatically close?
a. Upstream pressure below minimum
b. Pack overheat
c. Engine start sequence
d. Engine FIRE pushbutton on the related side pressed
e. DITCHING pushbutton is selected
What does an amber FAULT light in the HOT AIR pushbutton indicate?
Duct overheat - the Hot Air and Trim Air valves close automatically
How many Air Conditioning System Controllers are there?
- Each Air Conditioning System Controller has 2 lanes – (Active/Standby)