AIR CONDITIONING PANEL Flashcards

1
Q

The pneumatic system is monitored and controlled by?

A

2 Bleed Monitoring Computers (BMC)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

If one BMC fails, can the other take over?

A

a. Yes, they are interconnected. If BMC 1 fails:
b. APU and ENG 1 leak detection are not monitored
c. ECAM APU BLEED LEAK warning is lost

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The PACK FLOW selector has LO, NORM, and HI positions (A319/320). What does this allow us to do?

A

Select pack flow rates representing LO 80%, NORM 100%, and HIGH 120% of NORM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What flow rate is automatically selected when APU bleed air is in use or during single pack operation?

A

Hi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When should the PACK FLOW selector not be in the normal position?

A

a. Less than 115 guests, select LO
b. Hot and humid conditions, select HI
c. During Smoke/Fumes removal, select HI as per the procedure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

If the engine bleed air in-flight is too low what will occur?

A

Engine speed is automatically increased to provide adequate bleed air pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What would cause an amber FAULT light to illuminate in the PACK 1 and/or Pack 2 pushbutton (OOD)?

A

a. Overheat - Pack outlet
b. Overheat - Compressor outlet
c. Discontinuity - Switch position disagreement with pack flow control valve
d. Note: FAULT light will be illuminated when no bleed air is supplied

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What does the amber FAULT light in the APU BLEED pushbutton indicate?

A

Bleed leak (APU bleed valve closes)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What causes the amber FAULT light on the ENG 1 BLEED and/or ENG 2 BLEED pushbutton (OOLD)?

A

a. Overpressure - Downstream of the bleed valve
b. Overheat
c. Leak - Low pressure
d. Discontinuity - APU bleed valve open and engine bleed valve not closed or
e. Engine Start with bleed valve not closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What are the two functions of the engine bleed valves?

A

a. Pressure regulation

b. Shut off valves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

At what cabin differential pressure does the RAM AIR valve open?

A

1 PSI ΔP or less

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What logic controls the X-Bleed valve when the X-BLEED switch is in AUTO?

A

a. When APU bleed valve is OPEN, the X-Bleed valve is open
b. When APU bleed valve is CLOSED, the X-Bleed valve is closed
c. X-Bleed also CLOSES for wing, pylon, or APU duct leak (except during engine start)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What causes the Pack Flow Control valve to automatically close?

A

a. Upstream pressure below minimum
b. Pack overheat
c. Engine start sequence
d. Engine FIRE pushbutton on the related side pressed
e. DITCHING pushbutton is selected

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What does an amber FAULT light in the HOT AIR pushbutton indicate?

A

Duct overheat - the Hot Air and Trim Air valves close automatically

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

How many Air Conditioning System Controllers are there?

A
  1. Each Air Conditioning System Controller has 2 lanes – (Active/Standby)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Describe how the Air Conditioning System Controllers regulate temperature?

A

a. Basic temperature regulation: Both packs produce the required outlet temperature determined by the lowest demanded zone
temperature
b. Optimized temperature regulation: Hot air is added to the individual zones by the trim air valves to maintain the desired zone
temperatures

17
Q

What occurs when an active lane of an Air Conditioning System Controller fails?

A

The second lane takes over

18
Q

What occurs when both lanes of an Air Conditioning System Controller fails?

A

The related pack is lost. The hot air pressure regulating valve and associated trim air valve(s) close

19
Q

How does the Air Conditioning System Controller configure its associated pack ram air inlet flap for takeoff and
landing to avoid the ingestion of foreign matter?

A

a. Takeoff: Pack Ram Air Inlet Flap closes when takeoff power is set and the main landing gear struts are compressed.
Reopens after main landing gear strut extension
b. Landing: Pack Ram Air Inlet Flap closes as soon as the main landing gear struts are compressed and speed ≥ 70 knots.
Opens 20 seconds after speed

20
Q

If an air cycle machine (ACM) fails, what occurs?

A

The affected pack will operate as a heat exchanger

21
Q

What effect will the engine start sequence have on the pack flow control valves?

A

The pack flow control valve will close automatically

22
Q

After engine start with the APU BLEED pushbutton ON, what source is supplying bleed air to the packs?

A

APU Bleed

23
Q

When does the Lav/Galley Extract Fan operate?

A

Continuously when electrical power is available