Air Conditioning Flashcards
What is the purpose of the ram air?
An emergency ram air inlet ventilates the cockpit and cabin to remove smoke or if both packs fail.
What is the function of the mixer unit?
This unit mixes cold fresh air from the packs with the cabin air being recirculated through recirculation fans.
What is the function of the trim air valves?
These valves are electrically controlled by the air conditioning system controllers. The cockpit trim air valve and the cabin trim air valves adjust the temperature by adding hot air.
What is the function of the APU flow demand?
When the APU bleed valve is open the air conditioning system controller signals the APUs Electronic Control Box (ECB) to increase the APU flow output when any zone temperature demand cannot satisfied.
For which zones is an independent temperature control possible?
Cockpit fwd cabin and aft cabin.
Is a temperature control from the cabin possible?
Yes during cruise the cabin crew can modify each cabin zone temperature that is selected from the cockpit with a limited authority of +/- 2 5°C or +/-4 5°F.
What is the function of the pack flow control valve?
This valve regulates the air flow in accordance with signals received from the air conditioning system controllers.
What is the temperature selection range?
The temperature selection range is from 18°C (64°F) to 30°C (86°F).
Under which condition should the pack flow controller be set to LO?
With a low passenger load to reduce bleed air demand and improve fuel efficiency.
Under which circumstances delivers the air conditioning system high flow?
In single pack operation or when the APU is supplying bleed air.
Under which condition should the pack flow controller be set to HI?
With a high passenger load in hot conditions in order to help reduce the cabin temperature.
What happens to the pack flow control valves during engine start?
They automatically close.
How is the pack flow control valve controlled and operated?
The valve is electrically controlled and pneumatically operated.
The PACK FLOW controller is set to NORM and the ECAM display shows PACK FLOW to be high. How is this possible?
High flow is automatically selected regardless of PACK FLOW sel position because air is only being supplied by the APU.
In which cases closes the pack flow control valve?
The Pack flow control valve closes automatically in case of pack overheating engine starting or operation of the fire or ditching pushbutton.