Air Condiotining Flashcards

1
Q

Quais são os componentes do air conditioning system ?

A
2 air conditioning system controllers 
2 air conditioning packs 
Trim air 
Ram air 
Cabin recirculation fans 
Avionics ventilations
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Quais são as três zonas de operação do air conditioning system ?

A

Cockpit
Aft cabin
FWd cabin

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

O que as packs recebem de pressão das engine bleeds e apu bleeds or ground source ?

A

High pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Como a pack e operada para obter temperatura independe para as 3 zonas ?

A

Packs operam junto à trim air system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

O que faz a mixing unit ?

A

Mistura o ar das packs com o ar recirculado e distribui para as três zonas

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

O que regula o resfriamento do air flow ?

A

Dois air conditioning system controllers onde cada um possui dois canais

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

O que o air conditioning system controller one controls ?

A

Pack one
Hot air regulating valve
Cockpit trim air valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

O que o air conditioning system controller two controls ?

A

Pack 2

Fwd and aft trim air valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Quando em cruzeiro quanto podemos modificar a temperatura das zonas ?

A

Mais ou menos 2,5 graus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Como e controlado o hot airflow de todas trim air valves ?

A

Controlado pelo hot air pressure regulator valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Quando em solo a aeronave poderá ter ar condicionado através da ground e para onde vai esse ar ?

A

Direto pra mixing unit antes de ser distribuído

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

O que é a Ram air ?

A

Usada durante emergência para gerar cabin ventilation during depressurization

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Quando a ram air e utilizada ?

A

Durante o voo abaixo de 10000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

QuNdo a válvula de ram o air não irá abrir ?

A

Se o diferencial de pressão passar de 1psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

O que controla o automatic ventilation system?

A

Aevc avionic equipments ventilations computer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

O que faz o avionic ventilations system?

A

Resfria os avionics e parte elétrica

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Qual é o ar que o avionics ventilations system USA ?

A

External air
Conditioned air
Skin heat exchanger air cooling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Como é feita a ventilação na bateria ?

A

Venturi skin of the aircraft draw air from the space around the batteries and vents overboard

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Como é feito a ventilação dos lavatórios e da galley

A

An extraction fan draws ambient cabin air through the lavatories and valleys and exhaust it near the outflow valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Which of the air conditioning system controllers controls the cabin zone temperature ?

A

Air conditioning system controllers 2

21
Q

Which of these ecam pages display information about the air conditioning system?

A

Crise Cond bleed press

22
Q

What is the purpose of the ram air system?

A

To ventilate the cockipir and cabin when unpressurized and no packs are operating

23
Q

When the air conditioning system will close the pack flow control valve ?

A

Packs overheat
Fire pushbutton is pressed of engine
Ditching se is selected ON (cabin press )

24
Q

O que acontece no solo com a pack depois da primeira engine start do dia ?

A

Abre após 30s mas atrasa um minuto pra a segunda engine ser ligada

25
Como é feito a cooling das packs ?
Pack driven cooling fan e em voo a cooling air é dada pela ram air
26
Quando a temperatura que sai do compressor fica em âmbar ?
Acima de 260graus
27
O que o water separator system faz?
Dries air before enters the turbin section
28
O que faz a bypass valve ?
Control output temperature of the air from this pack
29
Pack outlet temperature
25 normally green | 91 becomes amber after 90
30
Em situações anormais o que acontece com a hot air pressure regulating valve if the ducts overheat, cabin and cockpit trim air valves fails ? To
Air conditioning controller close de hot valve
31
The hot air pressure regulating valve remains operative when aft and fwd cabin trim air valve fails ?
No, just one .
32
QuNdo a ram air inlet flaps fecha ?
Durante a decolagem quando set TO power Durante o pouso até 70kt Ela abrirá 20s depois que a velocidade cair de 70kt
33
Qual é a temperatura do max e min das zonas de acordo com a seleção do cold or hot no air conditioning system?
18 | 30
34
Como funciona a pack selector ?
De acordo com o número de passageiros Lo 80% - below 115 pax Norm 100% Hi 120% - hot and humid conditions
35
Quando a pack pode ser colocada em HI?
Single engine operation | apu supply bleed air
36
If one lane of an air conditioning system controller fail ...
The remaining lane takes over and the operation remains normal
37
RegArdless of the selected flow rate the system delivers high flow when In single pack operation or ....
When apu is supply bleed air
38
Como o AEVC pode ser controlada ? | Avionic equipment ventilation computer
Automaticamente ou manualmente através do BLOWER pb e EXTRAT pb durante abnormal conditions
39
O que acontece quando apenas o BLOWER Pb OVRD
Blower fan stop and the air conditioning inlet valves opens to supply cooling air
40
O que acontece quando o extrat pb ovrd ?
Both fan continue run and the skin exchanger inlet bypass valve closes to force all recirculating air over the skit heat exchanger
41
O que acontece quando é detectado smoke ?
Cause blower fault and extract fault warning O blower fecha e o extrat continua aberto Todas as válvulas fecham menos a do ar condicionado inlet
42
O que acontece quando o aevc fail ?
Skin exhxhange isolation valve remains open The inlet valve and skin exchange bypass valve remains in their last position And the extract fan continue operate
43
What is the normal configuration of avionic ventilation system during flight ?
Closed circuit
44
What is the normal configuration of avionic ventilation system on the ground during warm day ?
Open circuit
45
Which fan will the crew be directed to select to OVRD when the smoke configuration needs to be set ?
Both BLower and extract fans
46
The fwd compartment has only an isolation valve sw and temperature selector ?
True
47
If a duct overheat is sensed in the hot air system, the amber fault light in the hot air sw will illuminate, and the hot air vAlve will close automatically l.
True
48
Whenever the cardio door is ... such as upon arrival at the gate, the hot air valve automatically closes l, shutting off heat to the cargo compartment. To
Open
49
With the isolation sw in .... if smoke is detected in the cargo compartment both isolation valves automatically close displaying as cross line amber on ECAM.
Auto